Skip to content
UNICOAT CTE Coal Tar Epoxy
UNICOATCoatings

UNICOAT CTECoal Tar Epoxy Protective Coating

Coal tar epoxy protective coating

UNICOAT™ CTE is a two-component, high-solids, solvent-based coal tar epoxy that protects steel and concrete in immersion service. It builds up to 200 microns dry film per coat and cures to a hard, smooth, durable film.

About UNICOAT CTE Coal Tar Epoxy

UNICOAT™ CTE is a two-component, high-solids coal tar epoxy coating based on solvent. It protects steel and concrete in immersion service, can be built up to 200 microns dry film thickness, and cures to a hard, smooth, durable film.

It is a dependable and cost-effective protective coating against corrosion on steel and concrete in aggressive environments, including immersed and underground structures.

Advantages

  • Brush, roller or spray applied
  • Up to 200 microns DFT per coat
  • Fresh water and sea water immersion
  • Resists sewage, chemicals and abrasion
  • Suits buried and underground structures
  • High solids, 75% by volume
  • Hard, smooth and durable film
  • Protects both steel and concrete
  • Long-lasting corrosion protection
  • Cost-effective heavy-duty coating

Where it is used

  • Water and wastewater: sewage treatment plants, sumps, manholes and drains
  • Marine and immersion: jetties, piles, barges and ballast tanks in fresh or sea water
  • Tanks and pipework: linings for tanks, pipes and trenches carrying crude and petroleum products
  • Industrial plants: steel and concrete in paper mills, chemical plants and similar industries
  • Buried structures: underground steel and concrete exposed to aggressive soil

Specifications

From the UNICOAT CTE Coal Tar Epoxy technical data sheet. Check the latest TDS for your submittal.

TypeTwo-component, high-solids, solvent-based coal tar epoxy
FinishSemi-gloss
ColourBlack / Brown
Solids content75% ± 2 by volume
Mixing ratio16 : 4 by volume, Part A : Part B (4 : 1)
Recommended no. of coats2
Recommended dry-film thickness200µ
Calculated coverage (200µ / coat)3 – 4 m²/L depending on surface and application
Pot life @ 25°C4 hours (shorter above 30°C)
Drying @ 25°C10 days (full cure)
Application temperature10 – 35°C, out of direct sunlight
Application methodsAirless, rollers or conventional spray; brush or roller
CleanerXylene
Chemical resistance (immersion)Acids and alkalies very good; solvents good; salts and water excellent
Packaging20L / set (16L + 4L)
Shelf life12 months below 30°C, out of direct sunlight and rain

Questions about UNICOAT CTE Coal Tar Epoxy

Where is UNICOAT CTE used?

Sewage treatment plants, sumps, manholes and drains; jetties, piles, barges and ballast tanks in fresh or sea water; linings for tanks, pipes and trenches carrying crude and petroleum products; steel and concrete in paper mills and chemical plants; and buried steel and concrete in aggressive soil.

How many coats and what thickness?

Two coats at a recommended 200 microns dry film. Calculated coverage is 3 – 4 m² per litre per coat at 200 microns, depending on the surface and application. An extra coat may be needed to reach the specified thickness.

What surface preparation is needed?

Steel in non-immersion service: abrasive blast clean to SSPC-SP-6 (Sa 2) Commercial Blast. Immersion service: SSPC-SP-10 (Sa 2½) Near White Metal. New concrete must cure 28 days and then be brush-off blasted.

How do I mix it, and what is the pot life?

Stir each part separately with a drill and paddle, pour all of Part B into Part A and mix 2 – 3 minutes until smooth. Do not mix partial kits. Pot life is 4 hours at 25°C and shorter above 30°C.

What spray equipment is needed?

Airless spray with a 28:1 or higher pump ratio and a 0.021 – 0.025 inch tip, or industrial conventional spray with separate air and fluid regulators, a pot agitator and a moisture trap. Brush and roller also work; avoid runs and sags.

What should it not be used for?

Not for immersion in aromatic or ketone solvents or strong oxidising acids. Apply only between 10 – 35°C out of direct sunlight, use only the recommended thinner (xylene for cleaning) and never use mixed material beyond its pot life.

Is it flammable?

Yes. Keep away from heat, sparks and flame, ventilate well (forced ventilation in enclosed spaces), wear solvent-resistant gloves, goggles and overalls, and use a respirator when spraying or in confined spaces.

Drawings & CAD details

2 editable CAD details (DXF / DWG). Free to download, no sign-up.

All UNICOAT CAD details

UR-CT-D02UNICOAT

UNICOAT Basement Retaining Wall External Face

For illustration only – not for construction. Generic product details, not an engineering design. Sizes, reinforcement and installation to be designed and approved by the project engineer. Refer to the TDS.

More from UNICOAT

All UNICOAT products

Request a quotation

Leave your details and we reply by email or WhatsApp, usually within the same working day.