UNISEAL® VT-629Fire Rated MS Polymer Sealant
MS fire rated hybrid sealant
UNISEAL® VT-629 is a single-component, moisture-curing MS polymer joint sealant for fire-rated movement joints. Sealed on both faces over UNIFLEX® PE FR, it achieves up to 4 hours to BS EN 1366-4.
- Technical data sheetReadPDF · 3.5 MB
- Drawings & CAD details (3)View & download
- Test report, MSDSOn request
About UNISEAL® VT-629 Fire Rated Sealant
UNISEAL® VT-629 is a single-component, moisture-curing joint sealant based on advanced MS polymer technology, giving movement capability in fire-rated joints. Sealed on both faces of the joint, it achieves a fire rating of up to 4 hours to BS EN 1366-4.
It is isocyanate- and solvent-free, so it can be applied to damp surfaces without bubbling or shrinkage. It bonds to most substrates, can be painted with common industrial paints, and is low VOC and halogen-free.
The 4-hour system was tested on 20 – 50 mm joints in walls and floors at least 150 mm thick, primed with UNISEAL® PRIMER and sealed over UNIFLEX® PE FR fire retardant fillerboard. No backer rod is used: standard backer rods are not fire rated.
UNISEAL® VT-629 is manufactured by Vital Technical Sdn Bhd (V-TECH) and supplied by Unity Reliance (M) Sdn Bhd.
Advantages
- Up to 4 hours fire rating (BS EN 1366-4), both faces sealed
- JBPM (Bomba) firestop certified
- ASTM C920 compliant – ±25% movement capability
- Good UV resistance
- Low static charge – less dirt streaking
- Paintable with common industrial paints
- Isocyanate-free – no air bubbling
- Solvent-free – no shrinkage
- Halogen-free, low VOC formulation
Where it is used
- Fire-rated movement joints
- Precast and in-situ concrete
- Expansion and construction joints
- Tilt-up construction
- Interior and exterior fire compartments
- Brick and blockwork
- Fibre cement board and plasterboard
- Underground tunnels
Specifications
From the UNISEAL® VT-629 Fire Rated Sealant technical data sheet. Check the latest TDS for your submittal.
Estimate how much you need →| Material | MS polymer (hybrid), single-component, moisture curing |
|---|---|
| Colour | Grey (supplied in black sausage foil) |
| Appearance | Non-sag thixotropic paste |
| Fire resistance (BS EN 1366-4) | Up to 4 hours – both faces sealed (20 – 50 mm joints, walls / floors ≥ 150 mm, primed, over UNIFLEX® PE FR) |
| Movement capability (ASTM C719) | ±25% |
| Specific gravity | 1.62 |
| Tack-free time (25°C, 50% RH) | 20 – 60 minutes |
| Cure depth (24 hrs, 23°C, 50% RH) | Approx. 3 mm |
| Full cure | 7 days |
| Shore A hardness (ASTM C661) | ≥ 25 |
| Tensile strength (ASTM D412) | ≥ 1.0 N/mm² |
| Elongation at break (ASTM D412) | ≥ 200% |
| Service temperature | -20°C to +90°C |
| Application temperature | +5°C to +40°C |
| VOC (USEPA Method 24) | < 50 g/L (SCAQMD Rule 1168) |
| Standards | BS EN 1366-4:2021; AS 1530.4:2014; ASTM C920; RoHS I, RoHS II & SVHC |
| Size & packing | 600 ml sausage, 20 per carton. UNISEAL® PRIMER: 1 litre tin |
| Shelf life | 12 months unopened, stored dry and cool (around 25°C) |
Questions about UNISEAL® VT-629 Fire Rated Sealant
What fire rating does UNISEAL® VT-629 have?
Up to 4 hours to BS EN 1366-4, when both faces of the joint are sealed. The tested system is 20 – 50 mm joints in walls or floors at least 150 mm thick, primed with UNISEAL® PRIMER and sealed over UNIFLEX® PE FR fire retardant fillerboard. Sealing only one face gives a much lower rating.
Is UNISEAL® VT-629 Bomba certified?
For the current Bomba fire stop certificate and test documents for UNISEAL® VT-629, please contact Unity Reliance and we will send you the latest copy.
Do I use a backer rod?
No. A standard backer rod is not fire rated. Fill the joint core with UNIFLEX® PE FR fire retardant fillerboard, set back from each face by the sealant depth, and gun the sealant directly onto it.
Do I need to prime the joint?
Yes for fire-rated joints. Brush UNISEAL® PRIMER on both joint faces and seal once it is tack-free; the fire rating was achieved on primed joints. Re-prime if the joint is not sealed within 3 hours.
How should the joint be sized?
Joints up to 12 mm wide use a 1:1 width to depth ratio; joints over 12 mm use 2:1. For the 4-hour rating keep the joint within 20 – 50 mm wide in walls or floors at least 150 mm thick, as tested.
How many metres does one sausage do?
Per sealed face, a 600 ml sausage fills about 6 m of a 10 x 10 mm joint, 3 m of a 20 mm wide x 10 mm deep joint, or 1.5 m of a 20 x 20 mm joint. A fire-rated joint sealed on both faces uses twice the quantity. Site wastage will vary.
Where should it not be used?
Not below the waterline or under permanent water immersion, not in trafficable joints, and not with alkyd resin paints. Limit exposure to solvents, oils and other chemicals.
Can it be painted over?
Yes, with common industrial paints once fully cured, but not with alkyd resin paints. Do a site trial first, as solvent paints can leave the sealant tacky.
Guides
Drawings & CAD details
1 PDF drawing sheet and 2 editable CAD details (DXF / DWG). Free to download, no sign-up.
For illustration only – not for construction. Generic product details, not an engineering design. Sizes, reinforcement and installation to be designed and approved by the project engineer. Refer to the TDS.