Guides & FAQ · Questions and answers
FAQ
415 answers on choosing, installing and ordering concrete joint and waterproofing products, from our data sheets, typical details and the questions customers ask us.
Waterstops
Cast-in PVC, rubber and copper waterstops for construction and expansion joints.
Full guideHow to choose a waterstop: PVC, rubber, swelling or copperWhat is a waterstop?
A waterstop is a strip cast into a concrete joint so water cannot travel along the joint between two pours. It is used in basements, water tanks, treatment plants, retaining walls and other structures that must stay watertight.
Which waterstop should I use for a construction joint and which for an expansion joint?
A construction joint (kicker or day joint) is not meant to open, so a construction profile without a centre bulb is used: UNISTOP® ICJ or ECJ, a rubber dumbbell, or a UNISWELL® swelling strip. An expansion joint opens and closes, so it needs a profile with a centre bulb: UNISTOP® IEJ or EEJ, a rubber centre-bulb waterstop or copper with a fold, together with filler board and sealant. Expansion profiles (IEJ, EEJ) also work at construction joints, but they cost more, so we only suggest them there if it is unclear from the drawing whether the joint is a construction or an expansion joint.
What do ICJ, IEJ, ECJ and EEJ mean?
They are the UNISTOP® PVC profile types. ICJ = internal construction joint, IEJ = internal expansion joint (with centre bulb), ECJ = external construction joint, EEJ = external expansion joint. Internal profiles are cast in the middle of the wall or slab; external profiles sit on the blinding under a base slab with the ribs facing up.
What is the difference between an internal and an external waterstop?
An internal waterstop is cast in the centre of the section, half in each pour, with its edge eyelets wire-tied to the reinforcement. An external waterstop is laid on the blinding under a base slab, ribs up, centred on the joint and nailed through the outer web to the stop-end formwork. External profiles are easier to place under slabs because they do not need to be held in the middle of the reinforcement.
What widths does UNISTOP® PVC waterstop come in?
UNISTOP® PVC waterstop comes in 150, 200, 250 and 320 mm widths, in rolls. The TDS lists the full profile range. The project engineer chooses the width. As a guideline in our typical details, sections 250 mm thick and above use a 250 mm profile, and thinner sections use 150 or 200 mm.
PVC, rubber or copper waterstop: which one should I choose?
UNISTOP® PVC is the general choice for basements, tanks, treatment plants and retaining walls. UNISTOP® NR natural rubber suits joints with larger or cyclic movement, settlement or seismic movement because of its high elasticity. UNISTOP® TPR thermoplastic rubber can be welded on site like PVC and also shares the high elasticity of natural rubber. UNISTOP® Copper (1 mm or 1.2 mm phosphorus non-arsenical copper) is used where water pressure is high and a long design life is needed, such as dams and spillways.
How are PVC waterstops joined on site?
PVC and TPR waterstops are heat-welded on site with a jig and heater blade, end to end. Lapped or taped joints are not acceptable. To reduce site welding, use factory-made intersections (tees, crosses and L pieces) at corners and junctions.
How do I join natural rubber waterstop on site?
Natural rubber cannot be heat-welded like PVC; it is spliced on site with a vulcanising kit. For projects with only a few joints, use the UNISTOP® Cold Kit: one kit does 5 joints and suits 150, 230 and 305 mm waterstops. For big projects with many joints, a hot vulcanising kit is the better choice because the overall cost per joint is lower than with the cold kit.
What are the most common mistakes when installing a waterstop?
Placing it off-centre (one side gets a short water path), not tying an internal profile to the reinforcement so it folds over during the pour, poor compaction leaving honeycombing around the flange (the most common leak path), and lapping instead of welding the joints.
Does an expansion joint need anything besides the waterstop?
Yes. An expansion joint works as a system: a centre-bulb waterstop, a full-depth UNIFLEX® filler board to form and fill the gap, and a UNISEAL® sealant on top, on a backer rod or the filler board, with primer.
Can a waterstop be added to a joint that is already cast?
A cast-in PVC or rubber waterstop cannot be added after the pour. For an existing construction joint, a UNISWELL® hydrophilic swelling strip can be bonded on the joint face before the next pour. A joint that is already leaking is usually repaired by injection with UNIFIX PU grout.
Do you have CAD details for waterstop joints?
Yes. The Downloads page has free CAD details in DXF for our products, including waterstop joints, plus full A3 PDF typical drawings. Download them with no sign-up.
Product questions
What sizes does UNISTOP® PVC Waterstop come in?
Each profile (ICJ, IEJ, ECJ, EEJ) comes in 150, 200, 250 and 320 mm widths. Roll lengths are 20m for 150mm, 15m for 200mm, 12m for 250mm and 15m for 320mm.
Which width should we use for our wall or slab?
As a rule of thumb, use a 250mm wide waterstop for concrete walls or slabs 250mm thick and above. For thinner sections, use the 150mm or 200mm profile that most closely matches the thickness.
When do we use an internal versus an external profile?
Internal profiles (ICJ/IEJ) are always used in wall joints of water retaining structures, and can also be used in roof and podium deck joints. External profiles (ECJ/EEJ) are generally used where there is positive water pressure directly on the waterstop, such as basements and tunnels, and also in base slabs of water retaining structures.
How is it fixed before the concrete pour?
Internal waterstops are centred on the joint and wired to the reinforcement through the brass eyelets on the edge flanges, with formwork clamping it in the middle. External waterstops are laid on the compacted grade or lean concrete and nailed through the outer web to the formwork.
How are joints and intersections made on site?
Lengths and the factory prefabricated intersections are hot welded using a jointing jig and electric heater blade, with at least 25mm protruding from the jig. The ends are melted and pressed together until the PVC cools to form a fusion welded butt joint.
How is an expansion joint formed with it?
Cast one side first, then fix UNIFLEX® PE filler board to the concrete face around the waterstop centre bulb for the full joint depth before casting the next pour against it.
Is UNISTOP® PVC suitable for drinking water tanks?
Yes. It is tested to MS 1583 and cytotoxicity test and SPAN approved for drinking water contact.
UNISTOP® Natural Rubber Waterstop
Which profile do I use?
DB (dumbbell) at construction joints and CB (centre bulb) at expansion joints, with the bulb in the joint gap. Each comes in 150, 230 and 305 mm widths.
How is it fixed?
Centre it on the joint and clamp it between split formwork so it cannot move, then compact the concrete fully around it. Never make holes through the waterstop. At expansion joints, cast one side, fix UNIFLEX® PE board either side of the bulb for the full joint depth, then cast the second side.
How are site joints made?
By vulcanising. Cut the ends square, wire-brush 75 mm back to a suede finish and clean with rubber cleaner. Then join with the UNISTOP® Hot Joint Kit (mould preheated to 130 – 150°C, about 25 – 30 minutes in the mould) or the Cold Joint Kit. Use factory intersections at junctions.
How much movement and pressure can it take?
Natural rubber gives 680% elongation and 16% compression set, so it follows large and cyclic movements and withstands high hydrostatic head. The joint design is by the project engineer.
What roll lengths are available?
20 m for 150 mm, 15 m for 230 mm and 12 m for 305 mm; custom lengths on request.
UNISTOP® Cold Kit Natural Rubber Waterstop
How many joints does one kit do?
One set completes 5 joints on UNISTOP® NR rubber waterstop. Order more sets for the number of site joints.
How is a cold joint made?
Cut both ends square and wire-brush 75 mm back to a suede finish. Clean with rubber cleaner and let it dry, apply rubber glue to both ends and faces and wait about 5 minutes, press the ends together aligned, then press a jointing strip centred over the joint on each face, working out air from the centre. Let it set before fixing.
Cold kit or hot kit?
The cold kit suits projects with only a few joints, repairs, and confined or remote areas without power. For large projects with many joints, the reusable UNISTOP® Hot Joint Kit gives a lower cost per joint but needs mains power. If the specification calls for hot vulcanised joints, use the hot kit.
Does it work on PVC waterstops?
No. It is for UNISTOP® NR rubber waterstops. PVC and TPR waterstops are heat-welded with a heater blade.
Is it flammable?
The rubber cleaner and glue are solvent-based and flammable: use them with good ventilation away from flames and sparks, and wear the cotton gloves provided.
UNISTOP® Hot Kit Natural Rubber Waterstop
How is a hot vulcanised joint made?
Cut the ends square, wire-brush 75 mm back and clean with rubber cleaner, then apply rubber solution and let it dry about 5 minutes. Preheat the mould about 30 minutes to 130 – 150°C, place 50 mm strips of compound at the ends, wrap a 75 mm band around the joint, clamp in the mould for 25 – 30 minutes, then cool about 20 minutes and inspect.
Hot kit or cold kit?
The hot kit is for large projects with many site joints: the press is reusable so the cost per joint is lower, but it needs mains power. The cold kit suits a few joints, repairs, and confined or remote areas without power.
What should I tell you when ordering?
The UNISTOP® NR profile (DB or CB) and width, because the mould is made to suit the profile.
What power does it need?
220 V single-phase, 50/60 Hz, 1.5 – 3.0 kW, connected to a properly earthed supply.
What safety precautions apply?
The mould and press reach 130 – 150°C: wear heat-resistant gloves and let it cool before moving. Keep cables dry, unplug before cleaning, and use the solvent-based cleaner and solution with ventilation away from flames.
UNISTOP® TPR Thermo Rubber Waterstop
How is UNISTOP® TPR jointed on site?
Cut both ends square, clean and dry, heat them together on an electric heater blade at about 180°C until they melt (without charring), then press them firmly together, aligned, and hold until cool. Limit site welds to straight butt joints and use factory L, T and X intersections at junctions.
Which profile do I use?
UNISTOP® TPR DB at construction joints and TPR CB at expansion joints, with the centre bulb left exposed in the joint gap, not cast into the concrete.
How is it fixed?
Centre it on the joint, clamp it in split formwork and tie the outer edges to the reinforcement with wire. Never nail or hole the waterstop. Compact the concrete fully around it.
TPR or natural rubber?
TPR welds on site with a heater blade like PVC, with no vulcanising kit. Natural rubber (UNISTOP® NR) has higher elongation (680% against 460%) for very large movements but needs hot or cold vulcanising.
What roll lengths are available?
20 m for 150 mm and 15 m for 230 and 305 mm; other packing on request.
Where is a copper waterstop used?
Where very high water pressure, high temperature or long life is needed: dams and spillways, culverts, bridges, reservoirs, marine structures, power plants and industrial structures.
How is it positioned?
With the centre fold on the joint line so half its width is cast into each pour, fixed to the reinforcement or formwork so it cannot move. At expansion joints, UNIFLEX® PE fillerboard goes the full joint depth, including inside the fold.
How are site joints made?
On straight runs only (factory intersections at changes of direction). Clean the ends with a wire brush and acetone, overlap 100 mm following the fold, clamp with a 0.05 – 0.10 mm gap, preheat if needed, tack-braze, then braze the full lap with SBA 250 or an approved equivalent.
What thicknesses and lengths are available?
1 mm and 1.2 mm, in 2 m and 4 m lengths. Other thicknesses, custom lengths and profiles on request.
What safety precautions apply to brazing?
It is hot work: clear flammables, keep an extinguisher nearby, ventilate (brazing fumes are harmful), and wear filter goggles, heat-resistant and cut-resistant gloves and long sleeves.
Swelling (hydrophilic) waterstops
UNISWELL® strips and rings that swell in contact with water to seal construction joints, pipes and form ties.
Full guideSwelling waterstop or PVC waterstop? When to use eachHow does a hydrophilic (swelling) waterstop work?
It is bonded on the joint surface and cast into the concrete. When water reaches it, it swells and presses against the concrete, closing the water path through the joint. It needs to be fully contained in concrete to work.
Can a swelling waterstop be used in an expansion joint?
No. UNISWELL® SW47, SW10 and SW20 are for non-movement construction joints only. An expansion joint that opens and closes needs a centre-bulb waterstop such as UNISTOP® IEJ or EEJ.
Swelling strip or PVC waterstop: which is better for a construction joint?
Both work if installed correctly. A swelling strip is easier in congested kicker joints, around pipes and in existing joints, and needs no welding. A PVC waterstop gives a defined cast-in water path and is often what specifications call for in tanks and treatment plants. Check what the specification asks for.
What is the difference between UNISWELL® SW47, SW10 and SW20?
SW47 is a butyl rubber hydrophilic strip, 25 x 19 mm, in 5 m rolls. SW10 (20 x 5 mm, 20 m rolls, red) and SW20 (20 x 10 mm, 10 m rolls, black) are chloroprene rubber hydrophilic strips. SW47 is the softest and most flexible; SW10 and SW20 are more rigid. All three need a sound, smooth, clean concrete surface so concrete cannot get underneath the strip. SW10 is thin, so it is mostly used on precast connections; for cast in situ concrete use SW47 or SW20. All three are for non-movement construction joints and are tested to MS 1583 and SPAN approved for drinking water contact.
How much concrete cover does a swelling strip need?
Our details show a minimum of 50 mm concrete cover to the strip on both sides. With too little cover the swelling pressure can crack the concrete.
How do I fix a swelling strip to the concrete?
Bond it with UNISTICK CA contact adhesive: a continuous band on the concrete plus a thin coat on the strip, on a sound, level surface with full contact and no gaps underneath. Alternatively set it in a 30 x 10 mm groove formed with a timber strip in the fresh concrete. Place it on the wall centreline at kicker joints, or at mid-depth in slab joints.
What happens if the swelling strip gets wet before the pour?
It starts swelling early, and pre-swelling from rain or standing water reduces what it can do later. Keep the strip dry until the concrete is placed.
How do I waterproof a pipe passing through a concrete wall?
Use UNISWELL® SW47. It is soft and sticky, so it wraps tightly round the pipe and bonds to it. Fit it round the pipe at mid-wall with the ends butted together. The strip must be fully cast in concrete.
How do I stop leaks through form tie holes?
Fit a UNISWELL® RING, a 5 mm thick hydrophilic ring, at the middle of each form tie or split bolt, sized to the tie diameter. Ring sizes run from 14 mm to 35 mm inside diameter.
Product questions
UNISWELL® SW10 Hydrophilic Waterstop
Where can UNISWELL® SW10 Hydrophilic Waterstop be used?
UNISWELL® SW10 Hydrophilic Waterstop is for non-movement construction joints, new or existing, where it is fully contained within the joint. Because it is thin, it is mostly used on precast connections. For cast in situ concrete, UNISWELL® SW47 or SW20 is the better choice, and at pipe penetrations SW47 bonds better.
Can I use it in an expansion joint?
No. The TDS states it should not be used in expansion joints or in concrete sections less than 150mm wide.
What size is it?
20mm x 5mm in 20m rolls, 8 rolls (160 meters) per carton.
How is it fixed at the joint?
SW10 is fairly rigid, so it needs a clean, smooth concrete surface; on a rough surface concrete can get underneath the strip. Brush a continuous bed of UNISTICK CA about 30mm wide along the joint line and a thin coat on the waterstop, wait 5 – 20 minutes for the solvent to evaporate, then press it firmly in place. Butt joint ends with full face contact, keep at least 50mm concrete cover, and compact the second pour well around it.
What if it gets wet before the second pour?
Check it for pre-expansion; if it has pre-expanded, remove that section and replace it with a new length, or dry it out before pouring.
What water pressure can it resist?
The TDS gives a hydrostatic head resistance of 70 m on a hydraulic rig tester, with an expansion volume rate above 300 %.
UNISWELL® SW20 Hydrophilic Waterstop
What joints is UNISWELL® SW20 Hydrophilic Waterstop used for?
It is for non-movement construction joints, new or existing, where it is fully contained within the joint. It should not be used in expansion joints or in concrete sections less than 150mm wide.
How does it seal the joint?
The hydrophilic groups swell on contact with water, creating a positive compression seal against the concrete joint faces. It has a slow expansion rate to avoid damaging freshly placed concrete.
How is it installed?
SW20 is fairly rigid, so it needs a clean, smooth concrete surface; on a rough surface concrete can get underneath the strip. Brush a continuous bed of UNISTICK CA about 30mm wide along the line of the waterstop (and a thin coat on the waterstop), wait 5 – 20 minutes for the solvent to evaporate, then press it firmly in place. Butt the ends tightly at joints and intersections; a cast-in groove formed with a timber strip is ideal for fresh concrete.
How much concrete cover does it need?
It requires a minimum 50mm clear cover in all directions, and the TDS recommends a concrete substrate of at least 20 N/mm² compressive strength.
What if it gets wet before the second pour?
Check it for pre-expansion; if it has swollen, dry it out or replace that section with a new length before pouring.
What size does it come in?
It is supplied as a 20mm x 10mm strip in 10m rolls, 8 rolls (80 meters) per carton.
UNISWELL® SW47 Hydrophilic Waterstop
Where is UNISWELL® SW47 Hydrophilic Waterstop used?
UNISWELL® SW47 Hydrophilic Waterstop is a butyl rubber hydrophilic waterstop for non-movement construction joints, new or existing, where it is fully contained within the joint. Typical joints are slab to slab, wall to wall, slab to wall, kicker to wall and pipe penetrations. It is the best UNISWELL® strip for pipe penetrations because it bonds better.
Can it be used in expansion joints?
No. The TDS states it should not be used in expansion joints or in concrete sections less than 150mm wide.
How is it installed at the joint?
On sound, smooth, clean concrete (minimum 20 N/mm², free from dust, oil and grease), brush a continuous bed of UNISTICK CA about 30 mm wide along the joint line plus a thin coat on the strip, wait 5 – 30 minutes, then press SW47 firmly in place with at least 50 mm concrete cover all round. Butt the ends tightly. Cast the second pour once the adhesive has dried.
What concrete cover does it need?
A minimum 50mm of concrete cover in all directions, and the TDS recommends concrete with a minimum compressive strength of 20N/mm².
What if it gets wet before the second pour?
Check for pre-expansion. If it has pre-expanded, dry it out or remove that section and replace it with a new length before pouring.
What size and packing is it supplied in?
25 mm x 19 mm in 5 m rolls, 6 rolls (30 m) per carton. UNISTICK CA adhesive comes in 1 litre tins and covers approximately 20 – 30 m per litre.
UNISWELL® RING Form Tie Waterstop
What is UNISWELL® RING Form Tie Waterstop used for?
UNISWELL® RING Form Tie Waterstop is a hydrophilic rubber ring fitted around form ties to seal form tie holes against water ingress. It swells in a controlled manner on contact with moisture to form a compression seal around the tie.
What sizes are available?
All rings are 5 mm thick, with I.D x O.D sizes of 14 x 40, 16 x 40, 18 x 40, 20 x 45, 25 x 50, 30 x 60 and 35 x 60 mm. Boxes hold 1000 pcs for I.D 14 to 20 mm and 500 pcs for I.D 25, 30 and 35 mm.
How do I pick the right size?
Measure the form tie diameter and choose a ring that fits snugly around it. Do not cut the ring; slide it into place.
How is it installed?
Clean the form tie and surrounding area, open the ring slightly to fit over the form tie, and position it at about the middle of the tie. Press it firmly into place and make sure it stays in position while it begins to expand with moisture from the concrete.
What water pressure can it resist?
The TDS gives a hydrostatic head resistance of 70 m on a hydraulic rig tester, with an expansion volume rate of >300 %.
Expansion joint fillers, backer rod and bond breakers
UNIFLEX® filler boards, backer rod, bond breaker tape and slip membrane.
Full guideExpansion joint filler board: PE, fibreboard, cork or fire rated?What is an expansion joint filler board for?
It forms the joint gap when the second pour is cast against the first, and stays in the joint as a compressible filler so the concrete can expand without spalling. It also gives the sealant something to sit on.
Which filler board should I use: PE, bituminous fibreboard or cork?
For most joints we recommend UNIFLEX® PE closed-cell polyethylene: it has no bitumen to bleed out, does not absorb water, does not rot, suits water-retaining structures and acts as its own bond breaker. It is also non-toxic: it holds a SPAN certificate and has passed the SIRIM cytotoxicity test and the MS 1583 drinking water test. UNIFLEX® RBCF cork is a natural, green product made from the bark of the cork oak, used where a cork filler is specified. UNIFLEX® FB bituminous fibreboard is an older product; we have found UNIFLEX® PE to be a better replacement. UNIFLEX® PE FR is for fire-rated joints.
Can UNIFLEX® PE replace bituminous fibreboard or cork in a specification?
Often yes, but the consultant has to approve it. If the specification names bituminous fibreboard (often to ASTM D1751) or cork (often ASTM D1752), ask for UNIFLEX® PE to be accepted as an alternative before ordering. We provide the TDS for the submittal.
What thicknesses and sheet sizes does UNIFLEX® PE come in?
UNIFLEX® PE comes in 2 m x 1 m sheets, 10, 12, 15, 20 and 25 mm thick, normally black. 30 mm and above, other sizes and other colours are on special order.
Is UNIFLEX® PE suitable for water tanks and water-retaining structures?
Yes. It is closed-cell, non-absorbent, rot proof and bitumen free, which is why it is our general recommendation for water-retaining structures, basements and tanks. It holds a SPAN certificate and has been SIRIM tested as non-toxic. Expansion joints in these structures usually also have a centre-bulb waterstop.
Do I need bond breaker tape over the filler board?
Not over UNIFLEX® PE or PE FR: closed-cell PE does not bond to the sealant. Over UNIFLEX® RBCF cork or UNIFLEX® FB fibreboard, put bond breaker tape on top of the board before sealing.
What size backer rod do I need?
Choose a UNIFLEX® PE backer rod about 25% larger than the joint width (the UNISEAL® PS data sheet allows 10 to 20%), so it stays in compression. Backer rod comes from 10 mm to 50 mm diameter. Push it in to the correct sealant depth without puncturing it.
What is a bond breaker tape for?
It stops the sealant bonding to the bottom of the joint, so the sealant only sticks to the two joint faces. Without it, a sealant bonded on three sides cannot stretch and splits when the joint opens. It is used in sealant grooves over construction joints and induced cracks, and over cork (RBCF) or fibreboard (FB) filler.
What is a slip membrane used for?
UNIFLEX® PE Slip Membrane is a pre-formed polyethylene strip laid between two concrete elements, for example between a column or wall and a slab. It acts as a separator so the two can slide on each other: without it, friction between the concrete faces as they move can cause cracks. It comes 300 mm wide in 50 m rolls.
What is used for a fire-rated expansion joint?
Our typical detail uses UNIFLEX® PE FR fire-retardant filler in the core, with UNISEAL® VT-629 fire-rated sealant gunned directly onto the board at each face (no backer rod – a standard backer rod is not fire rated), primed with UNISEAL® PRIMER, sealed on both faces for the 4-hour rating in 20 – 50 mm joints. Always follow the tested system on the fire certificate for the joint width and rating required.
Product questions
How is it installed?
Cast the first pour and strip the formwork. Cut the board to the slab depth, punch holes for any dowels, and zip-cut a top strip at the sealant depth through about 70% of the thickness. Fix the board against the joint face with the strip flush with the finished surface, using concrete nails or spot bonds of UNISTICK CA, then cast the second pour. When cured, pull out the strip and seal the clean slot with a UNISEAL® sealant.
Do I need bond breaker tape under the sealant?
No. Sealants do not bond to UNIFLEX® PE, so it acts as a natural bond breaker.
Can it be pushed into an existing joint?
No. It is installed before the second pour. For an existing joint, back the sealant with UNIFLEX® PE BACKER ROD.
Why zip-cut only 70% of the thickness?
The uncut 30% holds the top strip in place and stops concrete slipping into the slot during the second pour. The strip is pulled out after the concrete cures.
What sizes are available?
2m x 1m sheets in 10, 12, 15, 20 and 25 mm, black. 30 mm and above and other sizes are on special order.
Is it suitable for water tanks and drinking water?
Yes. It is bitumen-free, rot-proof and non-tainting, tested to MS 1583 and cytotoxicity test, and SPAN approved for drinking water contact.
Is it fire rated?
No. For a joint that needs a fire retardant filler, use UNIFLEX® PE FR, which is also the base for the UNISEAL® VT-629 4-hour fire-rated joint.
UNIFLEX® PE-FR Fire Retardant Filler Board
What is UNIFLEX® PE FR used for?
As a fire retardant joint filler in expansion and movement joints in concrete, masonry and partition walls, and as the core of the UNISEAL® VT-629 fire-rated joint.
How is it used in a 4-hour fire-rated joint?
Fill the joint core with UNIFLEX® PE FR set back from each face by the sealant depth, prime both faces with UNISEAL® PRIMER, and gun UNISEAL® VT-629 directly onto the board on both faces. No backer rod is used. The 4-hour rating to BS EN 1366-4 covers 20 – 50 mm joints in walls or floors at least 150 mm thick. See drawing UR-SL-03.
How is it installed?
Cast the first pour and strip the formwork. Cut the board to the slab depth, punch holes for any dowels, and zip-cut a top strip at the sealant depth through about 70% of the thickness. Fix the board against the joint face with the strip flush with the finished surface, using concrete nails or spot bonds of UNISTICK CA, then cast the second pour. When cured, pull out the strip and seal the clean slot with a UNISEAL® sealant.
What sizes are available?
1.2 m wide rolls: 10, 12 and 15 mm x 60 m, 20 mm x 40 m and 25 mm x 30 m, grey. Other sizes on request.
Can it be pushed into an existing joint?
No. It is installed before the second pour. For existing joints, back the sealant with UNIFLEX® PE BACKER ROD (not for fire-rated joints).
Do you have a fire certificate for it?
Ask us for the current fire documents for UNIFLEX® PE FR and for the UNISEAL® VT-629 joint system when you prepare your submission.
UNIFLEX® FB Bituminous Fibreboard
Can I seal directly onto UNIFLEX® FB?
Only with bitumen-based sealants such as UNISEAL® BITUFLEX. PU, PS and MS sealants must not touch the board, because the mobile bitumen in it can degrade them. Separate them with UNIFLEX® PE Bond Breaker Tape or Backer Rod.
What sizes are available?
Sheets of 2.44 m x 1.22 m or 2.20 m x 1.22 m in 10, 12, 18 and 25 mm thickness. Strips can be cut to width on request.
How is the sealant slot formed?
Either place a removable timber former on top of the board, or install the board to full slab depth and cut it back to the sealant depth later. The second method suits estate roads and heavy-traffic areas that are sealed after all adjacent work is finished.
Can it be used as a protection board?
Yes. Fix it to the waterproofing coating or membrane with a compatible adhesive in full contact; it protects the membrane from puncture during backfilling or concreting.
Where should it not be used?
Not in joints that are permanently wet or submerged. For water-retaining structures use the closed-cell UNIFLEX® PE Filler Board.
How should it be stored?
Under cover in dry conditions. As with all organic materials, prolonged storage in wet or damp conditions carries a slight risk of spontaneous combustion.
UNIFLEX® RBCF Resin Bonded Cork Filler
Why choose cork for a water tank joint?
UNIFLEX® RBCF contains no bitumen or tar, is non-tainting, and swells when wet so the joint stays tightly packed even as it opens.
How is it installed?
After the first pour, cut the board to the joint length and to the slab depth less the sealing slot, drill for dowels, and fix it with spot bonds of UNISTICK CA (or concrete nails). Place a timber former on top to form the slot, cast the second pour, then remove the former. Alternatively fix it full depth and cut it back later.
Do I need bond breaker tape?
Yes. Lay UNIFLEX® PE Bond Breaker Tape over the cork so the sealant bonds only to the two joint faces, then seal with a UNISEAL® sealant.
What sizes are available?
915 x 610 mm sheets in 10, 12, 20 and 25 mm thickness.
How should it be stored?
Flat, under cover, dry and clear of the ground; shelf life is 12 months. As with all organic materials, prolonged wet storage carries a slight risk of spontaneous combustion.
What size backer rod should I use?
A diameter about 25% larger than the joint width, so the rod stays compressed and in place while sealing. For example, a 20 mm joint takes a 25 mm rod.
Why use a backer rod?
It sets the sealant depth at the correct width-to-depth ratio and stops the sealant bonding to the base of the joint (three-sided adhesion), so the sealant can move freely with the joint.
How is it installed?
Clean the joint, cut the rod to length with a sharp knife and press it in with a blunt tool to leave the specified sealant depth. Do not puncture, stretch or twist it, then seal with a UNISEAL® sealant.
Is it suitable for drinking water tanks?
Yes. It is bitumen-free and rot-proof, tested to MS 1583 and cytotoxicity test, and SPAN approved for drinking water contact.
What sizes are available?
10, 15, 20, 25 and 30 mm diameter in continuous lengths of 50 to 400 m per box, and 40 and 50 mm in 2 m lengths, 25 lengths (50 m) per box. Other sizes on request.
Should it be used in a fire-rated joint?
No. A standard backer rod is not fire rated; the UNISEAL® VT-629 fire-rated system uses UNIFLEX® PE FR fillerboard as the backing instead.
When do I use bond breaker tape instead of backer rod?
Where the sealant slot is too shallow for a backer rod, or where the sealant sits directly on a filler board or a flat base. The tape covers the base of the slot so the sealant bonds only to the two sides.
Is it needed over UNIFLEX® FB bituminous board?
Yes, for PU, PS and MS sealants. Bitumen in the FB board can degrade elastomeric sealants, so the tape keeps them apart.
How is it installed?
Clean the joint, peel off the backing and press the tape along the full width and length of the base of the slot, then seal over it with a UNISEAL® sealant.
What sizes are available?
20, 25, 50 and 75 mm wide in 2 m lengths, 3 to 50 mm thick. Other sizes on request.
Is it suitable for drinking water tanks?
Yes. It is bitumen-free, tested to MS 1583 and cytotoxicity test, and SPAN approved for drinking water contact.
Where is UNIFLEX® PE Slip Membrane used?
Under slabs and beams on bearings, roof slabs on wall ledges, steel bearing plates, pipe supports and sliding wall joints of circular tanks, wherever a loaded joint must slide with low friction.
How is it installed?
On a clean, smooth, dry steel-float finished bearing, lay two layers formed into a sealed envelope, taping all edges and joints so grout cannot get between them. Stagger the joints. Bond the membrane to the bearing with UNISTICK CA (touch-dry, then roll it down) and cast the member above.
How low is the friction?
Static coefficient 0.140 and dynamic 0.120 to BS EN ISO 8295.
How is it supplied?
2 mm thick, 300 mm x 2 m strips, 25 strips per roll (50 m).
How is it used on circular tanks?
Form the membrane in short chord lengths with staggered joints, in two layers, as long as the safe bearing capacity is not exceeded. See drawing UR-FL-03.
Joint sealants
UNISEAL® polyurethane, polysulphide, MS polymer, hot-pour and fire-rated sealants.
Full guideSealing a concrete joint: sealant type, joint size and backer rodWhich sealant should I use for my joint?
General building, precast, parapet and floor joints: UNISEAL® PU. Higher-movement and trafficked joints: UNISEAL® PU PRO. Water-retaining structures, treatment plants, chemical areas and pavements: UNISEAL® PS polysulphide. Water works, tanks and pools: UNISEAL® MS. Roads, runways and bridge joints: UNISEAL® Bituflex hot-pour. Fire-rated joints: UNISEAL® VT-629.
How deep should the sealant be?
For joints wider than 12 mm our details use a sealant width to depth ratio of 2:1, so a 20 mm wide joint gets about 10 mm of sealant. For joints up to 12 mm wide the UNISEAL® PU TDS uses 1:1. Too deep and the sealant cannot stretch; too shallow and it tears.
Why do joint sealants fail?
Usually not because of the sealant itself, but because of the wrong joint shape, dirty, wet or poorly prepared joint faces, or sealant stuck to the bottom of the joint (three-sided adhesion). Fix those and almost any good sealant lasts.
What is three-sided adhesion?
It is when the sealant bonds to both joint faces and the bottom of the groove. The sealant then cannot stretch when the joint opens, and it splits. A backer rod, PE filler board or bond breaker tape in the groove base prevents it.
Do I need a primer before applying the sealant?
Yes on porous surfaces. UNISEAL® PRIMER is required on concrete, mortar and masonry and in joints that will be immersed in water, and always on fire-rated VT-629 joints. On dry, sound, non-porous joints it is optional. Brush it on both clean, dry joint faces, let it dry 1 to 2 hours, and re-prime if the sealant is not applied within 3 hours.
What is the difference between PU and polysulphide (PS) sealant?
UNISEAL® PU is one-component polyurethane: no mixing, moisture curing, paintable, for general building joints. UNISEAL® PS is a two-component, chemically curing polysulphide with good chemical resistance, used in water-retaining structures, treatment plants, chemical areas and pavements.
Which sealant is suitable for water tanks and potable water areas?
UNISEAL® MS Polyether is a one-component MS polymer sealant formulated for the water industry: tanks, reservoirs, treatment plants and pools. It is tested to MS 1583 for contact with drinking water and passed the cytotoxicity test, and it stays permanently submerged. UNISEAL® PS polysulphide is also used in water-retaining structures and treatment plants for its chemical resistance; ask us for its test documents. Check any approval the project asks for before use in potable water.
How much movement can UNISEAL® sealants take?
UNISEAL® PU, PS and VT-629 each give a movement capability of plus or minus 25% in their TDS (total joint movement 50%). Size the joint so the expected movement stays within that.
Which sealant is used for road and runway joints?
UNISEAL® Bituflex, a hot-poured rubberised bitumen sealant, is used for roads, runways, toll plazas and bridge joints. It needs no primer and is finished slightly below the road surface so traffic does not drag it out.
Is there a fire-rated joint sealant?
Yes, UNISEAL® VT-629, an MS polymer sealant with a 4-hour fire rating to BS EN 1366-4 in its TDS. Use it within the tested system (joint width, backing and primer) on the fire test report.
How many metres of joint does one sausage of sealant fill?
It depends on the joint width and depth. Use the sealant calculator on our Calculators page: enter the joint size and length and it gives the number of 600 ml sausages and cartons.
What colours do the UNISEAL® sealants come in?
UNISEAL® PU and PU PRO come in white, grey and black. UNISEAL® PS and MS are grey. UNISEAL® VT-629 is grey. Bituflex and AP77 are black.
Product questions
What is UNISEAL® PU used for?
Expansion, control and perimeter joints in buildings, balconies, parapets, wet areas, door and window frames, roof and floor movement joints, precast panels, roads, bridges, airstrips and tunnels.
Do I need primer?
UNISEAL® PRIMER is required on porous substrates (concrete, mortar, masonry) and in joints that will be immersed in water. On dry, sound, non-porous joints it is optional, as UNISEAL® PU has good adhesion to clean, prepared surfaces. Let the primer dry 1 – 2 hours before sealing.
How should the joint be sized?
Joints up to 12 mm wide use a 1:1 width to depth ratio; joints over 12 mm use 2:1. Minimum depth 6 mm and maximum width 35 mm for vertical joints. Set the depth with UNIFLEX® PE Backer Rod (do not puncture it) so the sealant bonds to the two sides only.
How many metres does one sausage do?
A 600 ml sausage fills about 6 m of a 10 x 10 mm joint, 3 m of a 20 mm wide x 10 mm deep joint, or 1.5 m of a 20 x 20 mm joint (width x depth x length / 1000 = litres). Allow for site wastage.
What colours are available?
White, grey and black.
UNISEAL® PU or PU PRO?
UNISEAL® PU is the general building joint sealant. UNISEAL® PU PRO cures faster (3 – 4 mm per 24 hours, skin in 45 – 60 minutes), is classed ASTM C920 Use T1 for trafficked joints and resists fuels and Skydrol, so choose it for floors, roads, runways and stairs.
Can it be painted?
Yes, once fully cured, but solvent paints may make it tacky and some coatings may crack with movement, so field-test first.
Can UNISEAL® PU PRO take traffic?
Yes. It is classed ASTM C920 Use T1 for trafficked joints such as floors, stairs, roads, runways and pavements, and resists hydrocarbons, Skydrol and aviation fuel.
How fast does it cure?
It skins in 45 – 60 minutes and cures 3 – 4 mm per 24 hours at 23°C and 50% RH.
Do I need primer?
UNISEAL® PRIMER is required on porous substrates (concrete, mortar, masonry) and in joints that will be immersed in water. On dry, sound, non-porous joints it is optional, as UNISEAL® PU PRO has good adhesion to clean, prepared surfaces. Let the primer dry 1 – 2 hours before sealing.
How should the joint be sized?
Joints up to 12 mm wide use a 1:1 width to depth ratio; joints over 12 mm use 2:1. Minimum depth 6 mm and maximum width 35 mm for vertical joints. Set the depth with UNIFLEX® PE Backer Rod (do not puncture it) so the sealant bonds to the two sides only.
How many metres does one sausage do?
A 600 ml sausage fills about 6 m of a 10 x 10 mm joint, 3 m of a 20 mm wide x 10 mm deep joint, or 1.5 m of a 20 x 20 mm joint (width x depth x length / 1000 = litres). Allow for site wastage.
What colours are available?
White, grey and black.
Can it be painted?
Yes, once fully cured, and it is compatible with water-based paints. Solvent-based paints may make it tacky; field-test the coating first.
Is UNISEAL® MS POLYETHER safe for drinking water tanks?
It is tested to MS 1583 : Part 1 : 2003 for non-metallic products in contact with drinking water and passed the MS 1583 : Part 2 cytotoxicity test.
Can it stay under water permanently?
Yes. It is formulated to stay permanently submerged without losing adhesion or elasticity, and to stay watertight under hydrostatic pressure.
Do I need primer?
UNISEAL® PRIMER is required on porous substrates (concrete, mortar, masonry) and in joints that will be immersed in water. On dry, sound, non-porous joints it is optional. Let the primer dry 1 – 2 hours before sealing.
Can it be applied on a damp surface?
Yes, it cures even on damp or wet surfaces, but the joint faces must still be clean, sound and free of dust, oil and laitance.
How should the joint be sized?
Joints up to 12 mm wide use a 1:1 width to depth ratio; joints over 12 mm use 2:1. Minimum depth 6 mm and maximum width 35 mm for vertical joints. Set the depth with UNIFLEX® PE Backer Rod (do not puncture it) so the sealant bonds to the two sides only.
How many metres does one sausage do?
A 600 ml sausage fills about 6 m of a 10 x 10 mm joint, 3 m of a 20 mm wide x 10 mm deep joint, or 1.5 m of a 20 x 20 mm joint. Formula: width (mm) x depth (mm) x length (m) / 1000 = litres. Allow for site wastage.
Can it be painted?
Yes, after it is fully cured. Solvent-containing paints may make it tacky and some coatings may crack with movement, so do a field test first.
UNISEAL® VT-629 Fire Rated Sealant
What fire rating does UNISEAL® VT-629 have?
Up to 4 hours to BS EN 1366-4, when both faces of the joint are sealed. The tested system is 20 – 50 mm joints in walls or floors at least 150 mm thick, primed with UNISEAL® PRIMER and sealed over UNIFLEX® PE FR fire retardant fillerboard. Sealing only one face gives a much lower rating.
Is UNISEAL® VT-629 Bomba certified?
For the current Bomba fire stop certificate and test documents for UNISEAL® VT-629, please contact Unity Reliance and we will send you the latest copy.
Do I use a backer rod?
No. A standard backer rod is not fire rated. Fill the joint core with UNIFLEX® PE FR fire retardant fillerboard, set back from each face by the sealant depth, and gun the sealant directly onto it.
Do I need to prime the joint?
Yes for fire-rated joints. Brush UNISEAL® PRIMER on both joint faces and seal once it is tack-free; the fire rating was achieved on primed joints. Re-prime if the joint is not sealed within 3 hours.
How should the joint be sized?
Joints up to 12 mm wide use a 1:1 width to depth ratio; joints over 12 mm use 2:1. For the 4-hour rating keep the joint within 20 – 50 mm wide in walls or floors at least 150 mm thick, as tested.
How many metres does one sausage do?
Per sealed face, a 600 ml sausage fills about 6 m of a 10 x 10 mm joint, 3 m of a 20 mm wide x 10 mm deep joint, or 1.5 m of a 20 x 20 mm joint. A fire-rated joint sealed on both faces uses twice the quantity. Site wastage will vary.
Where should it not be used?
Not below the waterline or under permanent water immersion, not in trafficable joints, and not with alkyd resin paints. Limit exposure to solvents, oils and other chemicals.
Can it be painted over?
Yes, with common industrial paints once fully cured, but not with alkyd resin paints. Do a site trial first, as solvent paints can leave the sealant tacky.
UNISEAL® PS Polysulphide Sealant
What chemicals does UNISEAL® PS resist?
Fresh and salt water, dilute acids and alkalis, jet fuel, kerosene, petrol, diesel, crude oil, mineral and hydraulic oils, brake fluid, grease and alcohols are rated excellent in the TDS chart. Concentrated acids and alkalis (above 10%) and chlorinated solvents are moderate to poor; avoid prolonged contact.
How is it mixed?
Mix one complete kit at a time, never part kits, with a slow drill (300 – 400 rpm) and flat paddle for 2 – 3 minutes until the colour is uniform, scraping the sides and base. Load it into a barrel gun with a heavy-duty follower plate.
Do I need primer?
Yes on porous substrates and in immersed joints. Brush UNISEAL® PRIMER on before fitting the backer rod, let it dry 1 – 2 hours, and re-prime if the sealant is not installed within 3 hours.
How should the joint be sized?
Make the joint width at least 4 times the expected movement, with depth not more than the width: 1:1 for joints up to 12 mm and 2:1 for wider joints. Use UNIFLEX® PE Backer Rod 10 – 20% larger than the joint width.
How many metres does one 2.5 litre set do?
About 25 m of a 10 x 10 mm joint, 12.5 m of 20 mm wide x 10 mm deep, or 6.2 m of 20 x 20 mm. Formula: width x depth x length (m) / 1000 = litres.
How long before it can take traffic or water?
Initial cure is about 24 hours and final cure 7 days at standard conditions.
Can it be painted?
Yes, once fully cured, but solvent paints may make it tacky and some coatings may crack with movement, so field-test first.
UNISEAL® Bituflex Hot-Pour Sealant
Does BITUFLEX need a primer?
No, not under normal circumstances: it contains adhesion-promoting agents.
How is it installed?
Clean and dry the joint with a hot compressed-air lance, grit blasting or power brushing, removing old sealant. Insert caulking or backer rod to set the depth, heat BITUFLEX in a purpose-built pre-heater with agitator (never above 200°C), and pump or pour it with a bucket and V mould.
How full should the joint be?
In concrete, seal to about 1.5 – 3 mm below the surface so traffic does not pick up the sealant.
How much do I need?
About 0.47 kg per metre for a 20 x 20 mm joint, 0.76 kg for 25 x 25 mm and 1.12 kg for 30 x 30 mm. The full table is in the TDS; allow for wastage.
Can it be used over UNIFLEX® FB board?
Yes. Bitumen-based sealants such as BITUFLEX can be poured directly onto UNIFLEX® FB bituminous fibreboard.
What safety precautions apply?
Ventilate well, wear gloves at all times and a face shield where splashing is possible, keep water away from hot material, and never exceed the maximum temperature. If molten material touches skin, do not remove it; seek medical advice.
When is UNISEAL® PRIMER required?
On porous substrates such as concrete, mortar and masonry, in joints that will be immersed in water, and on fire-rated UNISEAL® VT-629 joints. On dry, sound, non-porous joints it is optional.
How is it applied?
On a clean, dry, sound surface (new concrete cured at least 14 days), mask the joint edges and brush the primer on undiluted. Let it dry 1 – 2 hours; apply two coats on very absorbent surfaces, and seal only when the last coat is fully dry.
How much primer do I need?
About 0.15 – 0.20 kg per m² of joint face. As a guide, 1 litre of primer serves about 30 – 50 litres of sealant.
How long can poured primer be used?
Pour only what you need into a clean container and use it within 30 minutes. Never pour unused primer back into the tin or dip a used brush into it.
Does it work on metal?
Yes, on aluminium and other metals, but polishing, coatings or finishes can reduce adhesion, so carry out a field adhesion test first.
Is it flammable?
Yes, highly flammable (flash point 24°C). Keep it away from flames, sparks and ignition sources, and wear neoprene gloves, goggles, a respirator and safety footwear.
Slab joints, dowels and crack inducers
Joints in ground slabs, industrial floors and pavements.
Full guideGround slab joints: expansion, contraction and construction jointsWhat joints does a ground slab need?
Usually three kinds: expansion (isolation) joints at walls, columns and between large bays; contraction (control) joints that make shrinkage crack in a straight line; and construction joints where one day's pour stops. The engineer sets the layout, spacing and depths.
What is a crack inducer?
A strip that creates a weak line in the slab so the shrinkage crack forms there instead of at random. UNIJOINT CI-T 30 or CI-T 50 is pressed into the fresh concrete on a string line, top flush with the surface; CI-B 75 is set upright on the lean concrete. As a rule of thumb the inducer depth should be at least a quarter of the slab thickness; the consultant confirms it.
Sawn joint or crack inducer: which is better?
Both create a contraction joint. A sawn joint must be cut as soon as the concrete allows; if it is sawn too late the slab cracks by itself first. A crack inducer is placed during the pour, so there is no timing risk with sawing.
What is a dowel cap and why is it needed?
A dowel bar transfers load across a slab joint. The UNIJOINT rubber dowel cap goes over the debonded half of the dowel, closed end, leaving a movement gap at the end. It restrains vertical movement, so the slabs stay level and do not settle when trucks pass over, while allowing horizontal movement so the slabs can expand and contract without cracking.
How are dowel bars installed in an expansion joint?
At mid-depth, parallel to the surface and square to the joint, supported on chairs. One half is bonded in the first pour; the other half is debonded with UNICOAT Bitumen 300 and fitted with a dowel cap. Put all dowel caps on the same side of the joint. Dowels that are not parallel or square lock the slabs together and cause cracking beside the joint.
How do I seal joints in an industrial floor?
Use UNISEAL® PU or, for trafficked joints, UNISEAL® PU PRO, with UNISEAL® PRIMER on the concrete joint faces, on backer rod or PE filler board, at a width to depth ratio of 2:1 for joints over 12 mm. For roads and pavements, hot-poured UNISEAL® Bituflex is used instead.
Product questions
What sizes are available?
Inner diameters of 25, 32, 40 and 42 mm (50 mm outer diameter) in 300 mm stock lengths. Choose the inner diameter to match the dowel bar; other lengths and sizes are made to order.
End cap or full-length cap?
Option A (end cap): coat the debonded half of the dowel with UNICOAT BITUMEN 300, let it dry, then push the cap over the end. Option B (full-length): the cap covers the whole debonded half and itself breaks the bond. The consultant specifies which.
Should the cap be pushed fully onto the dowel?
No. Leave the movement gap required by the design between the end of the bar and the closed end of the cap, and check the cap is a firm fit.
How are the dowels positioned?
At mid-depth of the slab, parallel to the surface and square to the joint, at the design spacing, with the capped half on the moving side (slab B). Support them on chairs or through the formwork so they cannot tilt or sag, and check alignment before and right after the pour.
Do you supply the dowel bars?
We supply the rubber dowel caps and UNICOAT BITUMEN 300 for debonding. Dowel bars are as per the structural design.
Which crack inducer do I choose?
The top type CI-T 30 or CI-T 50 is pressed into the fresh slab and finishes flush at the surface. The bottom type CI-B 75 sits on the lean concrete and is cast into the slab. Pick the height so it is at least a quarter of the slab thickness, and use only one type at a joint.
How is the top crack inducer installed?
After placing, compacting and levelling the slab, set a string line and press CI-T vertically into the fresh concrete, barbed tail first, until the head is flush. Re-compact the concrete on both sides, check it is straight and level, finish up to it without covering the head, and clean the head before the concrete sets.
How is the bottom crack inducer installed?
Before the pour, stand CI-B 75 upright on the lean concrete along the joint line and hold it with mortar packs on both sides. Place concrete beside it, not onto it, and compact carefully so it stays upright and on line.
How are lengths joined?
Cut square with a fine-tooth saw or sharp knife and butt the lengths tightly end to end so the joint line is continuous. Cut neatly at intersections so the profiles meet without gaps.
Can it replace an expansion joint?
No. Crack inducers form contraction joints only; they are not structural expansion joints.
Bridge and building expansion joints, bearings
UNIJOINT bridge joints, AP77 plug joints, seismic covers and rubber bearings.
What types of bridge expansion joint do you supply?
Strip seal joints (UNIJOINT CL SERIES section steel joints), steel-elastomer modular joints (UNIJOINT RJ, from 50 to 330 mm total movement) and UNISEAL® AP77 asphaltic plug joints. The right type depends on the movement the bridge designer calculates.
What is an asphaltic plug joint?
A joint made of a hot-applied rubberised bitumen binder (UNISEAL® AP77) mixed with aggregate, laid in a block-out over a steel bridging plate. It gives a smooth, seamless surface across horizontal joints in bridges, roads, airfield aprons and pavements.
How much movement can a strip seal joint take?
UNIJOINT CL 100 takes plus or minus 40 mm (80 mm total), per the TDS. The seal opens from 10 mm fully closed to 90 mm fully open, and is set at 50 mm at installation unless the engineer directs otherwise.
What is a laminated rubber bearing?
A natural rubber pad with bonded steel plates inside. It carries the bridge or beam load while allowing rotation and horizontal movement. UNIJOINT rubber bearings are made and tested to BS 5400 Section 9.
What is the difference between a laminated bearing and a plain rubber strip?
A laminated bearing has steel plates inside, so it carries high loads with little bulging. A UNIJOINT plain rubber strip is non-reinforced natural or neoprene rubber, made to size, used under precast or steel components in buildings and short-span bridges and as the rubber membrane in bridge joint blockouts.
Can you help me pick a bearing size for my load?
Our calculator shortlists a UNIJOINT bearing or rubber strip for a given load. The bearing design and final size are confirmed by the engineer.
What is EA 1015 used for?
UNISTICK EA 1015 is a two-component structural epoxy for bonding match-cast faces of precast segmental bridges. It is spread on both faces, the segment is pressed home and a bead squeezes out all round. It can be applied to dry or damp substrates.
What is a seismic expansion joint cover?
A joint cover for building movement joints in floors, walls and ceilings that can take larger seismic movement. UNIJOINT FSM is for floors (joint widths 50 to 300 mm); UNIJOINT IL1 and I-IL1 are surface-mounted aluminium covers for walls and ceilings.
Product questions
UNISEAL® AP77 Asphaltic Plug Joint
How much AP77 do I need?
kg per linear metre = width (mm) x depth (mm) x 0.0016. A 10 x 25 mm joint takes about 0.40 kg/m and a 30 x 25 mm joint about 1.20 kg/m; allow for site wastage.
Does it need a primer?
Yes, on concrete, stone and brick paving: prime with UNICOAT BITUMEN 300, let it dry at least 30 minutes, and pour within 6 hours. Never pour onto a damp surface.
How is it heated?
In a kettle with a thermometer, oil jacket and stirrer. Pour at 180 - 200°C and never above 200°C. Use within 2 hours of melting and do not re-heat material that has gone cold.
What aggregate is used in an asphaltic plug joint?
The TDS recommends aggregate with AAV max 5.0, PSV min 62, AIV max 16 and ACV max 10 to 25%.
What safety precautions apply?
Ventilate well and wear gloves, boots and overalls. Never let hot AP77 contact water, never heat a sealed container from the bottom, and keep a foam or dry powder extinguisher and sand at the kettle; never use water on a bitumen fire.
How is it packed?
20 kg cartons, with a shelf life of 36 months unopened in dry storage.
UNIJOINT Plain Rubber Strip / Pad
What sizes can be made?
Widths 50 – 600 mm, thicknesses 5 – 50 mm and lengths 1 – 20 m, in natural or neoprene rubber, made to the size ordered so no site cutting is needed.
How much load can it carry?
The TDS has a reference table per 1 m length; for example a 150 x 10 mm strip is listed at 450 kN and a 200 x 20 mm strip at 400 kN. These figures are for reference only: the bearing size and load must be designed and approved by the project engineer.
How is it installed?
On a sound, level, dry bearing, mark the position with at least 12 mm clear to every edge, bed the strip fully on mixed epoxy resin with no voids, press it down evenly and let the epoxy cure. Then lower the member on without dragging it.
Why keep a 12 mm gap at the edges?
Rubber spreads sideways when compressed, so it needs room on all sides.
Can it be used in bridge joints?
Yes, as the rubber sheet membrane laid on the blockout floor and continuous across the joint, with type and thickness to JKR or the engineer.
Strip or laminated bearing?
The plain strip is the economical choice for precast and steel connections and short spans. For bridge bearings with higher loads and movements, use the steel-reinforced UNIJOINT laminated rubber bearing as designed by the engineer.
UNIJOINT Laminated Rubber Bearing
What is UNIJOINT Laminated Rubber Bearing used for?
UNIJOINT Laminated Rubber Bearing supports bridge superstructures while accommodating horizontal thermal expansion, lateral movement and rotation. It is used for highway flyovers, elevated road bridges, rail and MRT viaducts and heavy civil structural joints.
What standard is it designed and tested to?
The bearings are manufactured and quality-tested in compliance with BS 5400: Section 9. Catalogue values are based on Serviceability Limit State per BS 5400 Section 9.1 Clause 10.1.4 and MS371, assuming dead load effect equal to live load effect.
What sizes are available?
Standard plan sizes run from 300 x 150 mm up to 600 x 400 mm, with overall thicknesses from 20 mm to 133.5 mm depending on the number and thickness of inner rubber layers. Custom sizes and non-standard load ratings are available on request.
How do I read the part number?
Taking RBP3015/2/06 as an example: RBP3015 is the plan size series (300 x 150 mm), /2 is the number of inner rubber layers, and /06 is the inner rubber layer thickness in mm.
How is the bearing installed?
Set level screws at the required plinth level, form an epoxy mortar plinth extending at least 20 mm beyond each bearing edge, and finish it flat to within ±1 mm with a textured, not glossy, surface. Place the bearing centrally once the plinth has cured, and do not load it until the plinth reaches full strength.
Are test reports available?
Yes. The rubber is tested to BS 5400: Section 9 and whole bearings are tested for compression stiffness at the design load (BS 5400-9.2, Clause 7.2). Custom bearings are tested at their design load, and test reports are available on request.
Where is UNIJOINT Compression Seal used?
UNIJOINT Compression Seal is a preformed elastic expansion joint seal for horizontal applications such as bridges, toll plazas, tunnels, podiums, parking areas and industrial floors. It can take vehicle to heavy vehicle traffic depending on the installation method.
What profiles are available and how much movement do they take?
Four sections: JS502 (16 mm movement), JS497 (25 mm), JB496 (30 mm) and JB610 (42 mm). Each suits a joint width range, from 22 - 38 mm for JS502 up to 34 - 76 mm for JB610.
How is it installed in the joint?
Clean and prime both joint walls and the seal sides, then apply mixed two-part epoxy adhesive to the joint walls and the ribbed walls of the seal. Ease the seal into the slot and drive it home with the 'Pogo Stick' applicator, then clean off excess adhesive before it cures.
How long before the joint can take load?
Allow the adhesive to cure 24 hours; maximum bond strength is usually achieved within 48 hours.
Does the joint width setting depend on temperature?
Yes. The TDS notes that the joint width setting must be related to the effective deck temperature at the time of construction.
How is it supplied?
In black, in 18 meter rolls, with weights from 1.3kg/m (JS502) to 3.8kg/m (JB610).
UNIJOINT FLEXSEAL Expansion Joint Seal
Is UNIJOINT FLEXSEAL an alternative to EMSEAL?
Yes, for building expansion joints. Both are foam expansion joint seals that sit flush in the joint and move with it. UNIJOINT FLEXSEAL is a closed-cell foam seal bonded to both joint faces with UNISTICK EA 5537 epoxy, made to the measured width of each joint and supplied from Malaysia. It is not the same product: compare the movement, load rating and fire requirements of each joint against both data sheets before substituting. EMSEAL is a trademark of its owner (a Sika company); Unity Reliance is not affiliated with it.
What joint widths can UNIJOINT FLEXSEAL seal?
Standard sizes cover gaps of 10 mm to 100 mm. Wider joints, including 150 mm and above, are made to order to the measured width.
How much movement does UNIJOINT FLEXSEAL take?
±40% of the gap width, 80% in total. For example, a 50 mm joint takes ±20 mm and a 100 mm joint takes ±40 mm.
Can vehicles drive over it?
Yes, within the load rating. Joints up to 63 mm are rated for car, reach truck and truck loads (Eurocode), at vehicle speeds not exceeding 16 km/h. Check the selection table in the TDS for your gap width.
How is UNIJOINT FLEXSEAL installed?
Clean and prepare both joint faces, coat both faces and both sides of the seal with mixed UNISTICK EA 5537 epoxy, then press the seal in flush with the finished surface. Each new 1 m length is butt-jointed to the last with UNISTICK CA contact adhesive. Protect the joint until the epoxy has cured.
Is UNIJOINT FLEXSEAL fire rated?
No fire rating is stated. Where the joint must be fire-rated, use a fire-rated joint detail such as UNISEAL® VT-629 (drawing UR-SL-03).
What do I need to give you to order?
The gap width (measured at several points, narrowest and widest), the seal height from the selection table, the total run length in metres, and whether the joint is floor-to-floor, floor-to-wall or wall-to-wall.
Where can I get the TDS and drawings?
The technical data sheet and the typical drawing UR-JT-06 are on this page. Typical drawings are for illustration only, not for construction, and are copyright of Unity Reliance (M) Sdn Bhd.
What is UNIJOINT CL SERIES?
A single-gap section steel expansion joint, also known as a strip seal joint, for bridges, viaducts and elevated roads. Two steel edge beams are anchored into the deck and a continuous neoprene W-seal is locked into both beams to keep the joint watertight.
How much movement can CL 100 take?
UNIJOINT CL 100 takes ±40 mm, 80 mm total. The seal opening at the road surface is 10 mm fully closed, 90 mm fully open and 50 mm at installation unless the engineer directs otherwise. Joint selection and blockout design are by the engineer.
What blockout does it need?
350 mm wide on each side and 250 mm deep, per the TDS. Weld Ø16 mm or larger anchorage bars to the reserved reinforcement every 2 to 3 bars, then pour epoxy-resin, steel-fibre or C40 to C50 high-strength concrete as specified.
Can the seal be replaced?
Yes. The W-seal can be replaced without removing the edge beams. Replace it immediately if leakage or tearing is found during routine cleaning.
How is UNIJOINT CL 100 installed?
Prepare the blockout, preset the seal opening to 50 mm with temporary frames, lower the joint in level with the finished surface and weld the anchor loops to the reserved reinforcement (Ø16 mm or larger) every 2 – 3 bars. Close the gap with formwork, pour C40 – C50 concrete, and loosen the temporary frames after initial set, no later than 2 hours. Fit the seal in one continuous length and pave 0 – 5 mm above the edge beams, never below.
What maintenance does it need?
Clear debris from the seal groove every 3 – 6 months. Every 12 months, check the seal for leaks or tears (replace at once if damaged), the edge beam to pavement interface for cracks, and the riding surface for smoothness and noise. Re-coat exposed steel with zinc-rich epoxy every 3 – 5 years.
What joint widths does the UNIJOINT FSM Seismic Joint cover?
Six models are listed, FSM-50 to FSM-300, for joint widths of 50, 100, 150, 200, 250 and 300 mm. All have a 35 mm installation height.
What movement can it take during an earthquake?
The system is designed for multi-directional movement, including lateral, vertical and longitudinal displacement, through an interlocking cover design. It also absorbs thermal expansion and contraction.
Can vehicles drive over it?
Per the TDS, FSM-50 and FSM-100 are rated for vehicle/lorry loads, while FSM-150 to FSM-300 are rated for vehicle loads.
What is it made of?
Aluminium extrusions and plates (6063-T5, 6061-T6 or 5052-H32) and 201/304 stainless steel plate, with a rubber gasket to prevent water penetration and limit metal noise. Surfaces in contact with masonry or concrete have a factory-applied protective coating.
Where is it typically installed?
Typical uses include airport terminals, exhibition centres, hospitals, museums, offices and hotels, residential buildings, shopping centres, rail and metro stations and data centres. The floor version is recessed into the concrete with a tile finish.
Where can I get the TDS and drawings?
The technical data sheet and any typical drawings or CAD details are available on this page; for a project submittal, ask Unity Reliance on WhatsApp. Typical drawings and CAD details are for illustration only, not for construction, and are copyright of Unity Reliance (M) Sdn Bhd.
UNIJOINT IL1 & I-IL1 Seismic Joint
Where is UNIJOINT IL1 & I-IL1 Seismic Joint used?
UNIJOINT IL1 & I-IL1 Seismic Joint is a seismic resistant expansion joint system designed for interior and exterior wall applications, including retrofit and surface mount installations. Typical buildings include airport terminals, hospitals, shopping centres, offices, hotels, rail stations and data centres.
What is the difference between IL1 and I-IL1?
IL1 is for wall-to-wall and ceiling-to-ceiling joints, while I-IL1 is for wall-to-corner and ceiling-to-wall joints. Both come in 50, 75, 100, 150 and 200 mm joint widths.
How much movement can it take?
Total movement ranges from +50/-25 mm for the 50 mm model to +50/-175 mm for the 200 mm model. The interlocking cover design allows multi-directional movement, including lateral, vertical and longitudinal displacement.
What is it made of and what length does it come in?
The extrusions are Aluminum 6063 T5, supplied in 3 metre lengths, with a rubber gasket to prevent water penetration and limit metal noise.
UNIJOINT Steel Elastomer Module Bridge Joint
Which UNIJOINT RJ model do I need?
Select by the total movement the bridge engineer gives: RJ 50, 65, 80, 100 (102 mm), 165, 230 or 330. Each model has its own module width, stud size and bolt torque, listed in the TDS.
How is it installed?
Saw-cut and break out a clean, level recess (module width plus nosing each side), lay levelling mortar on both shelves, drill and fix grade 8.8 anchor studs with bonding chemical, then bolt the modules tight end to end and torque the nuts to the TDS value. Seal the bolt holes and pour UNISEAL® AP77 nosings on both sides.
What goes either side of the modules?
UNISEAL® AP77 nosings, about 100 mm wide typically, poured flush between the module and the premix. Open to traffic only when the AP77 has cooled.
Is it waterproof?
It is substantially waterproof. Where JKR or the engineer specifies, a UNIJOINT rubber sheet membrane is looped into the gap below (see drawing UR-SY-02).
Can it handle skewed decks?
Yes, skew angles are accommodated. Give us the skew, movement and joint length when you enquire.
UNISTICK EA 1015 Epoxy Adhesive
What is UNISTICK EA 1015 used for?
Jointing precast elements, especially match-cast segments in segmental bridges, and high-strength bonding of concrete, steel, glass, wood and rubber.
How is it mixed?
Stir both parts, then combine one container of EA 1015-A with one of EA 1015-B (100 : 50 by weight) and mix with a low-speed drill until uniformly grey. Hand-mix only small quantities. Pot life is 140 – 180 minutes at 25°C.
Can it be applied to damp concrete?
Yes, it is designed for dry and damp substrates. Concrete must be sound, at least 14 days old and mechanically prepared to remove laitance; steel should be grit-blasted and degreased.
How is it applied to segment joints?
Butter both faces where possible, press the segments together under temporary stressing while it cures, and clean off excess. See drawing UR-SK-01 and UR-SY-02.
How strong is it?
Compressive strength above 85 N/mm² at 7 days, tensile above 30 N/mm², flexural above 40 N/mm², and slant shear bond to concrete fails in the concrete (FIP tests).
Waterproofing membranes, DPC, DPM and coatings
UNIPROOF membranes, UNIFIX torch-on membrane and tapes, UNICOAT coatings.
What is the difference between a DPC and a DPM?
A DPC (damp proof course) is a narrow strip laid in a brick or block wall to stop rising damp. A DPM (damp proof membrane) is a wide polyethylene sheet laid under a ground slab to stop moisture coming up through the slab.
How is UNIPROOF DPC installed?
It is laid in the mortar bed of the wall, embossed surface helping the mortar bond, with a minimum 150 mm lap at joints. It comes 110, 150 or 230 mm wide in 30 m rolls, 500 micron thick.
What is a self-adhesive waterproofing membrane?
UNIPROOF SA-15 is a cold-applied, self-adhesive SBS-modified bitumen membrane reinforced with polyester, with a polymer film on top. You peel off the release film and press it down on primed concrete, so no torch or flame is needed. It is 1.5 mm thick in 20 m x 1 m rolls and must be covered by a protection layer or screed.
Torch-on or self-adhesive membrane: which should I use?
A torch-on membrane such as UNIPROOF BITU-M (3.5 or 4.5 mm, slate surfaced) is heat-welded with a torch and suits exposed roofs. A self-adhesive membrane such as UNIPROOF SA-15 is applied cold, which is safer where a naked flame is not allowed. The specification and the roof or basement detail decide.
Water-based or solvent-based bitumen coating?
UNICOAT BITUMEN 300 is a water-based rubberised bitumen emulsion: low odour, can go on a damp surface, safe against XPS, sets in about 8 hours. UNICOAT BITUMEN 305 is solvent-based, needs a dry surface and sets faster (about 2 to 4 hours). Both dry to a black flexible membrane and also protect metal such as dowel bars.
What is coal tar epoxy used for?
UNICOAT CTE is a high-solids, two-component coal tar epoxy that protects steel and concrete in immersion service. It is also applied to the wall surfaces of sewage treatment plants (STP) to protect the concrete from chemical attack. The TDS recommends 2 coats.
What is an expansion joint tape, and how do I repair a leaking expansion joint?
UNIFIX TPE is a 1 mm thermoplastic elastomer tape, bonded across a joint or wide crack with epoxy adhesive, that stays elastic so the joint can move while staying sealed. It is the best way to repair a leaking expansion joint, because it bridges the joint without stopping it from moving. UNIFIX TPE-Felt has polyester felt on both sides for better bonding.
What is XPS insulation board used for?
UNIFLEX® XPS is a rigid extruded polystyrene board. It insulates roofs (on inverted roofs it is loose-laid over the membrane), floor slabs, basement and foundation walls and precast sandwich panels, and protects the waterproofing during backfilling. It comes 25 or 50 mm thick in two grades: XPS 250 (at least 250 kPa) and XPS 450 (at least 450 kPa, for heavily loaded slabs). Use only water-based coatings against it.
What is mould oil for?
UNICOAT Mould Oil is a ready-to-use release agent applied to formwork so the concrete does not stick. It suits aluminium and metal formwork; coverage is typically 15 to 18 m² per litre per coat depending on the surface.
Product questions
Which grade do I need?
XPS 250 for general insulation of roofs, walls and lightly loaded slabs; XPS 450 (≥ 450 kPa) under heavily loaded floor slabs.
Can I use solvent-based bitumen or adhesive with it?
No. Solvents dissolve polystyrene. Use water-based products such as UNICOAT BITUMEN 300 against UNIFLEX® XPS.
How is it used on an inverted roof?
Loose-lay the boards on top of the cured waterproofing membrane with tight, staggered joints, cover with filter fabric, then hold them down with pavers on pads or gravel ballast against wind uplift and flotation. Ballast, falls and drainage are designed by the consultant.
How is it used on basement walls?
Fix the boards tight against the coated wall to insulate it and protect the waterproofing, then backfill in compacted layers without damaging them.
What sizes and R-values?
25 and 50 mm, 1200 x 2400 mm or 600 x 1200 mm. R-value 0.89 m²K/W at 25 mm and 1.79 m²K/W at 50 mm.
Is it fire resistant?
No. It is combustible (UL 94 HB), so do not leave it exposed inside buildings; fire protection is designed by the consultant.
UNIFIX TPE-CJ Felt Chamfer Tape
Where is UNIFIX TPE-CJ FELT used?
On non-moving construction joints, wall / floor corners (in place of an angle fillet), parapet upturns, non-moving cracks, wet areas, roof decks, pools, tanks, lift pits and underground structures. For moving expansion joints use UNIFIX TPE-FELT.
Does it need epoxy adhesive?
No. It is bonded with the liquid or cementitious waterproofing coating it sits in.
How is it installed?
Apply the first coat of the waterproofing on both sides of the joint about the width of the felt, leaving about 5 cm in the middle uncoated. Lay the tape into the wet coat, press the felt in with a brush or roller, and keep the elastic centre unbonded. When dry, apply a second coat over the felt, then continue the main waterproofing over the area.
What about cracks wider than 3 mm?
Fill them with a suitable mastic before applying the tape, and prime if the waterproofing coating requires it.
What sizes are available?
120 mm wide (70 mm elastic centre) and 150 mm wide (100 mm elastic centre), in 50 m rolls.
How much water pressure does it resist?
More than 1.5 bar (EN 1928). For higher water pressure on moving joints use UNIFIX TPE or TPE-FELT, rated above 5 bar.
UNIFIX TPE Expansion Joint Tape
How is UNIFIX TPE installed?
Mix UNISTICK EA 5537 (A 3.4 kg + B 1.6 kg) and trowel it 1.0 – 1.5 mm thick on both edges of the joint, at least 40 mm wide each side for the 200 mm tape and 50 mm for the 300 mm tape. Press the tape into it with a roller, then apply a second 1.0 – 1.5 mm layer over the tape edges, overlapping at least 20 mm. Leave the centre unbonded.
How are lengths joined?
Weld them with a hot-air gun before application. UNISTICK EA 5537 cannot be used for splicing.
How much water pressure does it resist?
More than 5 bar (EN 1928).
When can the tape be loaded?
Only when the epoxy at the edges has fully cured. Do not move, lift or load it before then, and protect it from water and rain; curing is slower in cold weather.
Which tape do I choose: TPE, TPE-FELT or TPE-CJ FELT?
UNIFIX TPE and TPE-FELT are for moving expansion joints, bonded with UNISTICK EA 5537; the felt edges of TPE-FELT give the epoxy a mechanical key. UNIFIX TPE-CJ FELT is the lower-cost choice for non-moving construction joints and wall / floor corners, bonded with the waterproofing coating itself.
What sizes are available?
200mm x 1mm x 25m and 300mm x 1mm x 25m rolls, grey. Shelf life is 24 months unopened.
UNIFIX TPE-Felt Expansion Joint Tape
How is UNIFIX TPE-FELT installed?
Mix UNISTICK EA 5537 (A 3.4 kg + B 1.6 kg) and trowel it 1.0 – 1.5 mm thick on both edges of the joint, at least 50 mm each side. Roll the tape into it, then apply a second 1.0 – 1.5 mm layer over the felt edges, overlapping at least 20 mm past the edge. Keep the elastic centre unbonded.
How is it used as a concealed floor joint?
The tape sits in a recess below finished floor level. After it is bonded and cured, UNIFLEX® PE fillerboard goes over the elastic centre, non-shrink grout fills the recess on both sides flat to FFL (never on the elastic centre), and UNISEAL® PU seals over the fillerboard.
How are lengths joined?
Weld them with a hot-air gun before application; UNISTICK EA 5537 cannot be used for splicing.
When can it be loaded?
Only after the edge epoxy has fully cured. Do not move, lift or load it, and protect it from water and rain, until then.
Do I need TPE-FELT or TPE-CJ FELT?
TPE-FELT is for moving expansion joints and resists more than 5 bar. TPE-CJ FELT is the cost-saving choice for non-moving construction joints and is bonded with the waterproofing coating instead of epoxy.
What size is it?
300mm x 1mm x 25m roll, grey. Shelf life is 24 months unopened.
What is UNICOAT BITUMEN 300 used for?
It is a water-based bituminous liquid waterproofing coating for basements, retaining walls, slabs, foundations and wet areas such as bathrooms, kitchens, terraces, balconies and planter boxes. It also protects metal (pipes, dowel bars) against corrosion and works as a general bituminous primer.
Can it be applied on a damp surface?
Yes, the surface can be damp but must have no standing water. It must also be firm, clean and free of dust, grease, curing compound, laitance and loose material.
How many coats do I need and what is the coverage?
Prime with UNICOAT BITUMEN 300 diluted with 30 - 50% clean water at 0.5 litre per m² and let it dry (about 8 hours). Then apply at least two coats at right angles to each other, letting the first dry fully. Theoretical coverage is about 0.75 litre per m² per coat; add 10 - 15% for wastage.
Can it be reinforced?
Yes. For extra durability lay fibreglass fabric or mesh (such as UNICOAT CSM) into the first coat, apply the second coat while pressing the mesh with a pressure roller, and add a third coat if more build-up is needed.
When can it go under water?
After a curing period of 5 - 7 days, depending on temperature and humidity. Do not expose it to moving water while coating, and protect it from rain until fully cured.
Can it be used against XPS or polystyrene boards?
Yes. Being water-based it does not attack polystyrene, which is why our drawings use UNICOAT BITUMEN 300 against UNIFLEX® XPS; solvent-based coatings dissolve polystyrene.
What pack size and shelf life?
20 litre pail. Shelf life is 12 - 24 months in the unopened container kept dry; heat or humidity may reduce it.
What is UNICOAT BITUMEN 305 used for?
It is a solvent-based bituminous liquid membrane for basements, retaining walls, slabs, foundations and wet areas, a protective coating for metal and dowel bars, and a general bituminous primer.
Can it be applied on a damp surface?
No. The TDS asks for a structurally sound, clean and dry surface, free of dust, grease, curing compound, laitance and loose material. For a damp substrate use the water-based UNICOAT BITUMEN 300.
Should it be diluted?
No. It is supplied ready for use. Prime with undiluted 305 at 0.10 - 0.20 litre per m² and let it dry fully, typically 2 - 4 hours.
How many coats and what coverage?
At least two coats at right angles, letting the first dry fully. Theoretical coverage is about 0.3 - 0.5 litre per m² per coat; add 10 - 15% for wastage. Fibreglass mesh can be laid into the first coat for extra durability.
When can it be backfilled or go under water?
Protect it from rain, running water and moisture until fully cured. Under typical site conditions allow 5 - 7 days before backfilling, submersion or long-term water contact.
Is it flammable?
Yes. Keep it away from sparks, naked flames and hot work, apply only with good ventilation (forced ventilation in basements, tanks and pits) and wear gloves, goggles and overalls. Do not use it against polystyrene or XPS boards, as solvents dissolve them.
What pack size and shelf life?
20 litre pail. Shelf life is 12 - 24 months in the unopened container kept dry.
Where is UNICOAT CTE used?
Sewage treatment plants, sumps, manholes and drains; jetties, piles, barges and ballast tanks in fresh or sea water; linings for tanks, pipes and trenches carrying crude and petroleum products; steel and concrete in paper mills and chemical plants; and buried steel and concrete in aggressive soil.
How many coats and what thickness?
Two coats at a recommended 200 microns dry film. Calculated coverage is 3 – 4 m² per litre per coat at 200 microns, depending on the surface and application. An extra coat may be needed to reach the specified thickness.
What surface preparation is needed?
Steel in non-immersion service: abrasive blast clean to SSPC-SP-6 (Sa 2) Commercial Blast. Immersion service: SSPC-SP-10 (Sa 2½) Near White Metal. New concrete must cure 28 days and then be brush-off blasted.
How do I mix it, and what is the pot life?
Stir each part separately with a drill and paddle, pour all of Part B into Part A and mix 2 – 3 minutes until smooth. Do not mix partial kits. Pot life is 4 hours at 25°C and shorter above 30°C.
What spray equipment is needed?
Airless spray with a 28:1 or higher pump ratio and a 0.021 – 0.025 inch tip, or industrial conventional spray with separate air and fluid regulators, a pot agitator and a moisture trap. Brush and roller also work; avoid runs and sags.
What should it not be used for?
Not for immersion in aromatic or ketone solvents or strong oxidising acids. Apply only between 10 – 35°C out of direct sunlight, use only the recommended thinner (xylene for cleaning) and never use mixed material beyond its pot life.
Is it flammable?
Yes. Keep away from heat, sparks and flame, ventilate well (forced ventilation in enclosed spaces), wear solvent-resistant gloves, goggles and overalls, and use a respirator when spraying or in confined spaces.
UNICOAT CSM Chopped Strand Mat
What is UNICOAT CSM used for?
As the reinforcement layer in liquid-applied waterproofing such as UNICOAT BITUMEN coatings: roof slabs and gutters, wet areas, podium and terrace decks, planter boxes, water tanks, corners and upstands, and crack or joint reinforcement.
Which grade should I use?
CSM 100 for detailing at corners, joints and upstands; CSM 225 for general roof and wet-area waterproofing; CSM 450 for heavy-duty or high-build systems.
How is it installed?
Apply the first coat of waterproofing, lay UNICOAT CSM into the wet coat and roll it in until fully wetted out with no air pockets, then apply the next coat over it. Overlap adjacent lengths by at least 50 mm.
What roll sizes are available?
CSM 100: 1m x 50m (approx. 5 kg); CSM 225: 1.3m x 126m (approx. 37 kg); CSM 450: 1.04m x 64m (approx. 30 kg).
What safety precautions are needed?
Wear gloves, long sleeves and goggles, cut the mat in a well-ventilated area and avoid breathing fibre dust. If fibres get on the skin, rinse with cold water without rubbing.
What formwork is UNICOAT MOULD OIL for?
Aluminium, steel and other metal formwork, precast moulds and general shuttering. It is not recommended on plastic or resin-based formwork.
How do I apply it?
On clean, dry formwork free of oil, grease, dirt and old concrete, stir gently and apply a thin, uniform film by brush, roller or low-pressure spray with a fine nozzle. Drain and wipe off any surplus with a sponge or cloth. Apply one coat immediately before concreting.
What happens if I apply too much?
Over-application can cause dusting, staining or patchy concrete surfaces. Do not dilute it or mix it with other release agents.
What coverage can I expect?
Typically 15 – 18 m² per litre per coat, depending on the surface porosity and application method.
Are there cases where it should not be used?
Not on contaminated formwork or formwork treated with curing agents, and not where high early-strength surface finishes are needed without a site trial first.
How is it packed and stored?
206 litre drum. Store in the original closed container under shelter in a dry place at 5 – 40°C; shelf life is 12 months unopened.
How does UNICOAT SS harden concrete?
It soaks into the capillary pores and reacts with the free lime inside the concrete to form an insoluble crystalline structure. This densifies the concrete from within, so it works below the surface instead of leaving a film on top, and the concrete keeps its natural look.
How do I mix and apply it?
Dilute 28 kg of UNICOAT SS with 56 kg of water and mix until uniform; this covers about 840 m², depending on the surface. Apply by spray, roller or broom in at least two coats, letting the first coat dry for at least 2 hours. Keep foot traffic off until fully dry, typically at least 24 hours. Tools clean with water.
Can I apply it on new concrete?
Yes, once the concrete has cured for at least 14 days. It can also be applied to old concrete. The surface must be free of grease, wax, oil, paint, dust and loose material. A damp surface is acceptable, but there must be no standing water.
What results do the tests show?
In comparison tests on 1:3 mortar cubes, the treated cubes reached 34.4 N/mm² against 29.3 N/mm² untreated at 32 days, and 54.5 against 43.0 N/mm² at 225 days. In abrasion testing after 2000 cycles, weight loss was 5.16 g treated against 17.47 g untreated. Full figures are in the TDS.
Are there surfaces I should protect or avoid?
Do not use it on natural stone. Protect nearby wood, glass and metal with tape or sheeting, because the hardener may discolour them. It is non-toxic but alkaline, so wear gloves, goggles, protective clothing and safety boots, and rinse with clean water if it contacts skin or eyes.
UNIPROOF DPC Damp Proof Course
Which roll width do I need?
Choose 110, 150 or 230 mm to suit the wall. The 230 mm width covers a full-brick wall in one piece, without a longitudinal lap.
How is it installed?
Lay it flat and centred on a level, fresh mortar bed across the full wall width, with debris removed so nothing can puncture it. Lap at least 150 mm at ends, corners and intersections, then lay a fresh mortar bed straight over it before the next course.
How do I repair a tear?
Patch it with UNIPROOF DPC lapped at least 150 mm beyond the damaged area.
Can I use it with bitumen or solvent adhesives?
No. Solvent-based adhesives and bituminous compounds can degrade polyethylene.
Is it tested?
Yes, by SIRIM QAS International to ASTM D412: tensile strength above 20 MPa (machine direction) and elongation above 600%.
Which grade do I need?
Standard UNIPROOF DPM for general slab and site use, DPM HD (0.5 mm and above) for demanding sub-bases, and DPM VG (virgin-grade) where a clean, consistent film or a colour is required.
How is it laid under a slab?
On a level, compacted sub-base free of sharp stones and standing water, preferably with sand blinding or lean concrete. Overlap sheets at least 150 mm and tape all laps, turn the edges up above finished slab level, and use spacers under the reinforcement so the sheet is not punctured. Concrete as soon as possible after laying.
How do I repair a puncture?
Patch it with the same membrane, overlapping the damage at least 150 mm on all sides and taped on all edges.
What roll sizes are available?
DPM and DPM VG come in 12 ft x 180 ft rolls; DPM HD in 2 m x 25 m. Other sizes, thicknesses and colours on request.
Are there chemicals it should not touch?
Polyethylene is not recommended in contact with aromatic or chlorinated solvents, petroleum products or strong oxidising acids. Consult us before use on contaminated ground.
Which class of UNIPROOF EIM do I need?
Choose by the maximum working voltage of the equipment, not the withstand voltage. Class 0 covers up to 1,000 V (3 mm), Class 1 up to 7,500 V (5 mm), Class 2 up to 17,000 V (6 mm), Class 3 up to 26,500 V (8 mm) and Class 4 up to 36,000 V (12 mm).
What standard does it meet?
UNIPROOF EIM is tested to IEC 61111:2009 and BS EN 61111:2009, with mechanical and climatic properties to TNB KEJ08434:2013, and complies with RoHS 2011/65/EU. Test reports refer to the samples tested under the stated conditions.
How should the mat be laid and checked?
Lay it flat on a clean, dry floor with no curled edges, covering the full standing area in front of the equipment. Inspect it before each use and do not use a mat that is cut, punctured, blistered, cracked or contaminated with conductive material.
Is the mat enough on its own?
No. UNIPROOF EIM is a supplementary protective measure. Follow the site's safe working procedure and use appropriate PPE.
How do I clean it?
Clean with mild soap and water, avoiding abrasive tools that could cut or scratch the surface pattern. Make sure the mat is completely dry and free of cracks, pinholes or creases before returning it to service.
UNIPROOF SA-15 Self-Adhesive Membrane
Where can SA-15 be used instead of a torch-on membrane?
Anywhere a naked flame is not allowed, and over XPS or EPS insulation and timber: basements, foundations, retaining walls, podium and roof decks under screed, wet areas under tiles, sunken slabs, pitched roof underlay and vapour barriers.
How is it installed?
On a sound, clean, dry substrate above +5°C, prime with UNICOAT BITUMEN 305 and let it dry. Start at the lowest point, peel the release film progressively, press the membrane down from the centre outwards and roll it firmly. Side laps at least 50 mm, end laps at least 100 mm, staggered.
How is it finished on walls?
Take it at least 150 mm above finished floor level, fix the top edge with an aluminium termination bar sealed with UNISEAL® sealant, and reinforce corners, drains and pipes with an extra strip or collar. Form a 50 mm angle fillet at internal corners first.
Can it be left exposed?
No. It is not UV stable and not a trafficked surface. Protect it with UNIFLEX® XPS or PE board on walls (laid loose, not fixed through the membrane) and a protection screed on slabs, as soon as practical.
Can it be applied on a damp surface?
No. Do not apply in rain or on damp surfaces, and do not torch or heat the membrane.
What roll size is it?
20 m x 1 m rolls (20 m²), about 36 kg each, 1.5 mm thick.
UNIPROOF BITU-M Torch-On Membrane
Where is UNIPROOF BITU-M used?
UNIPROOF BITU-M is a slate-surfaced torch-on membrane for exposed waterproofing: flat and pitched roofs, balconies and roof terraces, parapets and copings, canopies, gutters and drainage channels, and precast or metal deck roofs. It can be torched over the existing surface for roof repairs and re-roofing.
What thickness and roll size does it come in?
3.5 mm and 4.5 mm, in 1m x 10m rolls weighing 35 kg and 60 kg per roll.
How is it installed?
Clean and repair the surface, then prime with UNICOAT BITUMEN 300 diluted with 30-50% clean water. Once the primer is touch-dry, start from the lowest point or drains and torch the membrane on with a propane gas torch, keeping side laps of at least 100 mm and end laps of 150 mm. Seal the laps with a heated round-tipped trowel, and at parapets turn the membrane up into a groove sealed with UNISEAL® joint sealant.
What if the primer has been left exposed too long?
If the primer is left exposed for more than 48 hours, clean the surface and apply a new coat before torching.
Can the laps be resealed by torching the top surface?
No. Lift and re-torch any unbonded area instead. Do not over-torch either, as this exposes and damages the reinforcement.
How should the rolls be stored?
Store rolls vertically in a shaded area, covered with thick fabric to minimise sunlight and UV, and do not stack pallets. Shelf life is 12 months if stored as recommended.
Leak repair and injection
UNIFIX PU injection grouts and injection machine.
How do I stop a leaking crack or joint in a basement?
Active leaks are usually stopped by PU injection: packers are drilled into the crack and UNIFIX PU grout is pumped in with an injection machine. The grout reacts with the water and foams to fill the crack. A specialist applicator should do the work.
Hydrophilic or hydrophobic PU grout: what is the difference?
UNIFIX PU60 is hydrophilic: it reacts with water to form a dense, flexible foam (foaming rate at least 350%), for running or gushing water and joints that move. UNIFIX PU200 is hydrophobic: it reacts fast, expands 2000 to 3000% and cures to a rigid, water-repellent seal, for non-moving cracks and voids that are damp or see wet-dry cycles.
What injection pump do I need for PU grout?
UNIFIX M-1500 is a high-pressure injection pump for PU and epoxy resins, up to 15,000 psi output. It weighs 7.5 kg, so it is easy to carry on site, and comes with a 5 m high-pressure hose and shut-off valve.
Can I seal a cracked concrete slab with epoxy?
A dry, non-moving structural crack can be repaired with epoxy. Use UNISTICK EA 5537: it is a flowable epoxy, so it runs into the crack and fills it. A crack that is still moving should be treated as a joint and sealed with a flexible sealant instead.
Product questions
When should I use PU60 rather than PU200?
PU60 is hydrophilic and cures to a dense, flexible foam, so it suits running or gushing water and cracks or joints that move. PU200 is hydrophobic and rigid, for non-moving cracks and voids that are damp or see wet-dry cycles.
Does it need a catalyst?
No. It is a single-component resin injected as supplied; the expansion depends on the water and moisture it meets.
How is it injected?
Drill 10 or 13 mm holes 40 – 50 mm from the leak at about 45° to intercept the crack, clean the hole, fit and tighten the packer (not too tight), then inject with the UNIFIX M-1500 holding about 5,000 psi for a few minutes per point. Re-inject until no leakage remains.
When can the packers be removed?
After 24 hours of cure. Break them off, remove cured grout from the surface and plug the holes with suitable mortar.
How do I clean the pump and tools?
With thinner immediately after use. Never use water, which reacts with the resin and blocks the equipment.
How should it be stored?
Dry and cool at around 20°C, away from direct sunlight; above 50°C insoluble solids may form. Shelf life is 12 months unopened. It contains isocyanates and is flammable before cure, so wear gloves, goggles and full-face protection during injection.
When should I use PU200 rather than PU60?
PU200 is hydrophobic and cures rigid with high tensile strength: use it for non-moving cracks, construction joints and voids that are damp or see wet-dry cycles. PU60 is hydrophilic and cures to a flexible foam: use it for running or gushing water and joints that move.
How is it injected?
Drill 10 or 13 mm holes 40 – 50 mm from the leak at about 45° to intercept the crack, clean the hole, fit and tighten the packer, then inject with the UNIFIX M-1500 holding about 5,000 psi for a few minutes per point. Re-inject until no leakage remains.
When can the packers be removed?
After 24 hours of cure. Break them off with pliers or a hammer, remove cured grout from the surface and plug the holes with suitable mortar.
How do I clean the pump and tools?
Flush with xylene immediately after use. Do not use water, which reacts with the resin and blocks the equipment.
How fast does it react?
Gel time is about 30 seconds and setting time about 648 seconds at 25°C, with 2000 - 3000% expansion.
How should it be stored?
Dry and cool at around 20°C, away from direct sunlight. Above 50°C insoluble solids may form. Shelf life is 12 months unopened. It contains isocyanates and is flammable before cure, so wear gloves, goggles and full-face protection during injection.
UNIFIX M-1500 Injection Machine
What can the UNIFIX M-1500 inject?
PU foam grouts such as UNIFIX PU200 and PU60, epoxy resins and other non-granular liquid injection materials.
How much pressure does it give?
Up to 15,000 psi within seconds; it restarts at 7,000 psi. The high-pressure hose is rated to 10,000 psi and the switch valve to 15,000 psi. For PU grout the TDS method holds about 5,000 psi at each packer for a few minutes.
What comes in the box?
A 910 W power drill, a 5 m high-pressure hose, a shut-off valve, a repairing kit, a seal set and a T-type wrench.
Which packers are available?
UNIFIX A10, A15, A20, A25 and A30 (13 mm diameter, 90 to 280 mm long, 50 per bag), UNIFIX B8 and B10 (10 mm diameter, 80 and 100 mm long, 100 per bag) and grease head connectors (10 per box). Drill the hole the same diameter as the packer.
How fine a crack can it seal?
The TDS states cracks as small as 0.01 mm, thanks to the immediate high-pressure output.
How do I clean it after PU injection?
Flush the pump, hose and tools immediately with xylene (or thinner). Never use water: it reacts with the PU resin and blocks the equipment.
Adhesives and epoxy
UNISTICK contact adhesive and epoxy adhesives.
Which adhesive bonds a swelling strip, cork or PE to concrete?
UNISTICK CA, a quick-drying solvent contact adhesive. It is made for bonding cork, closed-cell polyethylene and butyl rubber to concrete.
What is the difference between UNISTICK EA 33, EA 5537 and EA 1015?
EA 33 is a non-sagging epoxy paste for structural bonding. EA 5537 is a flowable epoxy adhesive grout, so it is the one for filling cracks and for grouting tile joints 1 to 10 mm wide on horizontal surfaces; it bonds to metal, wood, ceramic, PE filler board and rigid plastic. EA 1015 is a structural epoxy for segmental bridge joints that works on dry and damp surfaces.
How long do I have to use mixed epoxy?
It depends on the product and temperature. UNISTICK EA 33 and EA 5537 give about 30 minutes for a 100 g mass; EA 1015 gives 140 to 180 minutes at 25°C. Larger batches and hotter days shorten it, so mix only what you can place.
Product questions
How is UNISTICK EA 33 mixed?
Combine Part A and Part B 1 : 1 by weight and mix until the colour is uniform. Do not mix more than 1 kg at a time, as larger masses heat up and shorten the 30-minute pot life. Do not thin it with solvent.
Can it be used overhead?
Yes. It is a non-sagging paste for vertical and overhead surfaces and can be pressed into crack lines.
Can it be applied on damp surfaces?
No. Surfaces must be completely dry. For damp concrete use UNISTICK EA 1015.
How long before the bond can take load?
Handling strength develops in about 6 – 7 hours at 28°C; keep loading minimal until full strength after about 7 days. Small masses can be accelerated by heating to 80°C for 2 hours.
What pack sizes are available?
5 kg and 10 kg sets (Part A + Part B). Shelf life is 6 months from shipment when stored indoors at or below 30°C.
UNISTICK EA 5537 Epoxy Adhesive
How is it used with UNIFIX TPE tapes?
Trowel about 1.0 – 1.5 mm on both edges of the joint, 40 – 50 mm wide each side, roll the tape onto it, then apply a second 1.0 – 1.5 mm layer over the tape edges, overlapping at least 20 mm.
How is it used with UNIJOINT FLEXSEAL?
Coat both joint faces over the full depth of the seal and both sides of the seal, then press the seal in flush with the surface within the working time and remove excess before it cures.
How is it mixed?
Mix Part A (3.4 kg) and Part B (1.6 kg) until uniform, and only as much as you can use within the 30-minute pot life. Do not thin with solvent.
Can it be applied on damp concrete?
No. Surfaces must be completely dry, between 10°C and 35°C and out of direct sunlight.
When can the joint take water or load?
It is touch dry in about 3 hours at 28°C; protect it from water and loading until full cure, about 5 days at 28°C.
How much does a 5 kg set cover?
It depends on the joint and tape width. Tell us the joint length and tape width (200 or 300 mm) and we will estimate the sets needed.
How is UNISTICK CA applied?
Brush or spread it evenly on both clean, dry surfaces, wait until it is just tacky (about 5 – 30 minutes), then align carefully and press firmly together. It grabs immediately, so position it right first time.
How is it used with UNISWELL® strips?
Brush a continuous band about 30 mm wide along the waterstop line plus a thin coat on the strip, wait 5 – 30 minutes, then press the strip firmly in place. Cast the second pour only when the adhesive has dried. One litre does about 20 – 30 m of strip.
How is it used with filler boards?
Spot-bond UNIFLEX® PE or RBCF board to the hardened face of the first pour, full slab depth, so it stays in place during the second pour.
Is it flammable?
Yes, while wet: the solvents are highly flammable. Use it only with good ventilation and away from flames, sparks and hot work. Once cured it is non-flammable.
Can it be used on polystyrene?
Not stated in the TDS. Its solvents can damage some surfaces, so test a small area first; for XPS and EPS use water-based products.
Ordering, documents and delivery
Quotations, data sheets, drawings and delivery.
How do I get a quotation?
Send us the product, size and quantity on WhatsApp or through the Get a quote form on any page. If you have the drawing or BQ, send that and we will match the products.
Where can I download the technical data sheets?
All data sheets are on the Downloads page, free with no sign-up. If a TDS is not online yet, use the Request TDS button and we send it on WhatsApp.
Can you provide documents for a consultant submittal?
Yes. Each product has a technical data sheet, and we provide SIRIM test reports, MSDS, typical drawings and method statements on request for submittals.
Do you have free CAD drawings?
Yes. The Downloads page has editable CAD details in DXF (and DWG where available) and full A3 PDF typical drawings, free with no sign-up. They are typical details for illustration only, not for construction. All the drawings and CAD details are copyright of Unity Reliance (M) Sdn Bhd.
Do you deliver to site?
Yes, we deliver to project sites across Malaysia. Collection details are given with your quotation.
How do I work out how much material I need?
Our Calculators page estimates sealant, filler board and other quantities from your joint sizes and lengths, and shortlists bearings and rubber strips for a given load.
Can you recommend the right product for my joint?
Yes. Send us the joint detail or drawing, the joint width and movement, and what the structure is (tank, basement, road, building). We reply with the product, TDS and matching CAD detail.
Are the typical drawings and CAD details for construction?
No. They are generic product details for illustration only, not an engineering design. Joint layout, sizes, reinforcement and installation are designed and approved by the project engineer, and each product's TDS applies.
Where is Unity Reliance's office?
Our sales office (HQ) is in Kuala Lumpur. The address, phone numbers and map are on the Contact page.
No question matches that search. Ask us on WhatsApp.
Question not answered here?
Send us the joint detail, size and where it is. We reply with the product, TDS and CAD detail.
Answers are general guidance from our data sheets and typical details, not an engineering design. The project engineer confirms joint layout, sizes and products; each product's TDS applies.