Both stop water passing through a construction joint, but they work differently. A PVC waterstop blocks the joint with a long ribbed path cast half into each pour. A hydrophilic swelling strip (UNISWELL®) is bonded on the joint surface and swells when water reaches it, pressing against the concrete to close the path.
Quick comparison
| UNISWELL® swelling strip | UNISTOP® PVC waterstop | |
|---|---|---|
| Joint type | Non-movement construction joints only | Construction and expansion joints (centre-bulb profiles) |
| Installation | Bonded on the first pour with UNISTICK CA; no welding | Held in the reinforcement or on blinding; heat-welded at joins |
| Existing joints and retrofits | Yes, can be fixed to an existing joint face | Must be cast in |
| Pipes and form ties | Wrap round the pipe; UNISWELL® RING on form ties | Not practical |
| Main risks | Too little cover, swelling before the pour, poor bond | Displacement during the pour, poor compaction round the flange |
When a swelling strip is the better choice
- Kicker joints where holding a PVC profile in a congested cage is difficult.
- Pipe penetrations: wrap UNISWELL® SW47 round the pipe at mid-wall, ends butted. It is soft and sticky, so it hugs the pipe.
- Form ties and split bolts: a 5 mm thick UNISWELL® RING at the middle of each tie, sized to the tie diameter.
- Existing or day-work joints where a cast-in profile was never placed.
When you need a PVC (or rubber) waterstop
- Expansion joints that open and close: use a centre-bulb profile. Swelling strips are not for movement joints.
- Where the specification calls for a cast-in waterstop with a defined water path, typically for tanks and treatment plant structures.
Rules for swelling strips from our details
- Minimum 50 mm concrete cover to the strip on both sides. Too little cover and the swelling pressure can crack the concrete.
- Place it on the wall centreline (kicker joints) or at mid-depth (slab joints).
- Bond it with UNISTICK CA: a continuous band on the concrete plus a thin coat on the strip, on a sound, level surface with full contact and no gaps underneath. Alternatively set it in a 30 x 10 mm groove formed with a timber strip in the fresh concrete.
- Keep it dry until the pour. Pre-swelling from rain or standing water reduces what it can do later.
Unsure which suits your joint? Send us the section and we will recommend UNISWELL® or UNISTOP® and send the TDS and CAD detail.
Typical guidance only – not an engineering design. Joint layout, sizes and reinforcement are designed and approved by the project engineer. Refer to each product's TDS.